机构地区:[1]Cerklje na Gorenjskem, Trg Davorina Jenka, Cerklje na Gorenjskem [2]Clinical Institute of Radiology, University Medical Centre Ljubljana, Ljubljana, Slovenia [3]Department of Cardiology, University Medical Centre Ljubljana, Ljubljana, Slovenia [4]Department of Cardiovascular Surgery, University Medical Centre Ljubljana, Ljubljana, Slovenia
出 处:《International Journal of Clinical Medicine》2012年第7期603-606,共4页临床医学国际期刊(英文)
摘 要:Background: Transcatheter aortic valve implantation (TAVI) is a new method for patients with severe aortic stenosis at high surgical risk, such as previous cardiac surgery. The presence of mechanical mitral prosthesis might complicate TAVI because of possible interference between both prostheses. Some reports have already demonstrated the feasibility of TAVI in such patients. Case Reports: We report 2 patients with severe symptomatic aortic stenosis who had prior mitral valve replacement that successfully underwent TAVI with Edwards Sapien and CoreValve aortic prosthesis, re- spectively. Computed tomographic angiography (CTA) was useful for the assessment of the distance between both aor- tic and mitral prosthesis annuli. Transesophageal echocardiography was crucial for precise positioning of TAV. There were no special technical tips besides precise positioning of the valve prosthesis. In case of Core Valve the goal was the positioning at “zero point” and in case of Edwards Sapien valve a “half-on-half” position according to natural aortic valve. We observed no deformation or dysfunction of aortic and mitral prosthesis in any of the patients. Balloon valvu- loplasty prior to implantation helps to observe the mutual effect of the new aortic valve and pre-existent mitral prosthe- sis. Conclusions: We conclude that TAVI can be safely and successfully performed in patients with mechanical mitral prosthesis carefully considering the altered anatomical conditions. Skillfulness and TAVI experience of the operators should not be neglected.Background: Transcatheter aortic valve implantation (TAVI) is a new method for patients with severe aortic stenosis at high surgical risk, such as previous cardiac surgery. The presence of mechanical mitral prosthesis might complicate TAVI because of possible interference between both prostheses. Some reports have already demonstrated the feasibility of TAVI in such patients. Case Reports: We report 2 patients with severe symptomatic aortic stenosis who had prior mitral valve replacement that successfully underwent TAVI with Edwards Sapien and CoreValve aortic prosthesis, re- spectively. Computed tomographic angiography (CTA) was useful for the assessment of the distance between both aor- tic and mitral prosthesis annuli. Transesophageal echocardiography was crucial for precise positioning of TAV. There were no special technical tips besides precise positioning of the valve prosthesis. In case of Core Valve the goal was the positioning at “zero point” and in case of Edwards Sapien valve a “half-on-half” position according to natural aortic valve. We observed no deformation or dysfunction of aortic and mitral prosthesis in any of the patients. Balloon valvu- loplasty prior to implantation helps to observe the mutual effect of the new aortic valve and pre-existent mitral prosthe- sis. Conclusions: We conclude that TAVI can be safely and successfully performed in patients with mechanical mitral prosthesis carefully considering the altered anatomical conditions. Skillfulness and TAVI experience of the operators should not be neglected.
关 键 词:TAVI MITRAL Valve REPLACEMENT AORTIC PROSTHESIS MITRAL PROSTHESIS
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...