The Potential Sources of Transmitting of Hospital Acquired Infection by Routine Devices in Adult ICU in Alrass General Hospital  

The Potential Sources of Transmitting of Hospital Acquired Infection by Routine Devices in Adult ICU in Alrass General Hospital

在线阅读下载全文

作  者:Reem Dbas Alharbi[1] Amal Hussain Mohammed Ali[1] Ahmad Almatroudi[1] Shaimaa Mohamed[1] 

出  处:《Journal of Biosciences and Medicines》2020年第4期69-80,共12页生物科学与医学(英文)

摘  要:Hospital-acquired infections (HAI) reflect as a major global safety concern for both patients and health-care professionals. These infections could be in the form of cross-infection, endogenous infection and environmental Infection. Over 80% of these infections are related to devices’ utilization needed for patients’ life support. Methods show this is an observational and cross-sectional study, to identify the microorganism and determine the potential source of transmitting of hospital acquired infection by routine devices in adult ICU. The samples were collected using Amies transport media;three swabs were taken from the surfaces of indwelling urinary catheter, mechanical ventilation device and central venous catheter used from every twelve patients. The samples were cultured and analyzed by using microbiologic technique. Finally, all samples analyzed by MicroScan WalkAway 96 pulse. Results showing the most bacteria isolated are “Klebsiella pneumonia” (18.37%), “Acinetobacter baumannii” (11.48%), “Staphylococcus epidermidis” (4.59%), “Staphylococcus haemolyticus” (4.59%), “E. coli” (4.59%), “Serratia marcescens” (2.3%), “Pseudomonas luteola” (2.3%), “Kocurio kristinae” (2.3%) and “Photorhabdus luminscens” (2.3%). This study detects a high contamination of routine devices and resistant organisms. In the end it is recommended that effective infection control practices and effective strategies to control antibiotic-resistant bacteria should be applied.Hospital-acquired infections (HAI) reflect as a major global safety concern for both patients and health-care professionals. These infections could be in the form of cross-infection, endogenous infection and environmental Infection. Over 80% of these infections are related to devices’ utilization needed for patients’ life support. Methods show this is an observational and cross-sectional study, to identify the microorganism and determine the potential source of transmitting of hospital acquired infection by routine devices in adult ICU. The samples were collected using Amies transport media;three swabs were taken from the surfaces of indwelling urinary catheter, mechanical ventilation device and central venous catheter used from every twelve patients. The samples were cultured and analyzed by using microbiologic technique. Finally, all samples analyzed by MicroScan WalkAway 96 pulse. Results showing the most bacteria isolated are “Klebsiella pneumonia” (18.37%), “Acinetobacter baumannii” (11.48%), “Staphylococcus epidermidis” (4.59%), “Staphylococcus haemolyticus” (4.59%), “E. coli” (4.59%), “Serratia marcescens” (2.3%), “Pseudomonas luteola” (2.3%), “Kocurio kristinae” (2.3%) and “Photorhabdus luminscens” (2.3%). This study detects a high contamination of routine devices and resistant organisms. In the end it is recommended that effective infection control practices and effective strategies to control antibiotic-resistant bacteria should be applied.

关 键 词:Health-Acquired Infection ICU DEVICES CATHETERS Mechanical VENTILATOR Device 

分 类 号:R51[医药卫生—内科学]

 

参考文献:

正在载入数据...

 

二级参考文献:

正在载入数据...

 

耦合文献:

正在载入数据...

 

引证文献:

正在载入数据...

 

二级引证文献:

正在载入数据...

 

同被引文献:

正在载入数据...

 

相关期刊文献:

正在载入数据...

相关的主题
相关的作者对象
相关的机构对象