Is the Mock Transfer Enough Reliable to Evaluate Hysterometry for Embryo Transfer?  

Is the Mock Transfer Enough Reliable to Evaluate Hysterometry for Embryo Transfer?

在线阅读下载全文

作  者:Ana Touré Ecra Luc Nigué Noumoutié Kourouma Ana Touré Ecra;Luc Nigué;Noumoutié Kourouma(1General Hospital of Yopougon Attié, Abidjan, Cô,te d’Ivoire;Biostatistics Laboratory, Department of Medical Sciences, University Félix Houphouë,t-Boigny, Abidjan, Cô,te d’Ivoire;Dominique Ouattara Mother-Child Hospital, Bingerville, Cô,te d’Ivoire)

机构地区:[1]1General Hospital of Yopougon Attié, Abidjan, Cô,te d’Ivoire [2]Biostatistics Laboratory, Department of Medical Sciences, University Félix Houphouë,t-Boigny, Abidjan, Cô,te d’Ivoire [3]Dominique Ouattara Mother-Child Hospital, Bingerville, Cô,te d’Ivoire

出  处:《Open Journal of Obstetrics and Gynecology》2023年第3期516-527,共12页妇产科期刊(英文)

摘  要:Objectives: The aim of this study was to assess the reliability of the mock transfer during in vitro fertilization process Method: A case-control study was conducted on 134 patients included in IVF/ICSI cycles. From the hysterometry obtained during the mock transfer, the ideal embryo replacement site, i.e. two cm from the uterine fundus has been determined. Results: Significant differences were noted between the area estimated from the mock transfer and the area where the embryo was deposited during the actual embryo transfer. In fact, 15.9% of the patients had a difference between four and six cm, and 32% of the patients returning for a subsequent transfer had at least 2 cm of difference between the embryo deposit zones. This difference was significant (P 0.00) Conclusion: More than ultrasound guidance, the challenge with embryo transfer is to be able to minimize variations in the length of the uterus. This would make it possible to determine the ideal transfer depot area without multiple manipulations.Objectives: The aim of this study was to assess the reliability of the mock transfer during in vitro fertilization process Method: A case-control study was conducted on 134 patients included in IVF/ICSI cycles. From the hysterometry obtained during the mock transfer, the ideal embryo replacement site, i.e. two cm from the uterine fundus has been determined. Results: Significant differences were noted between the area estimated from the mock transfer and the area where the embryo was deposited during the actual embryo transfer. In fact, 15.9% of the patients had a difference between four and six cm, and 32% of the patients returning for a subsequent transfer had at least 2 cm of difference between the embryo deposit zones. This difference was significant (P 0.00) Conclusion: More than ultrasound guidance, the challenge with embryo transfer is to be able to minimize variations in the length of the uterus. This would make it possible to determine the ideal transfer depot area without multiple manipulations.

关 键 词:Mock Transfer Hysterometry Ultrasound Guidance Embryo Transfer 

分 类 号:R71[医药卫生—妇产科学]

 

参考文献:

正在载入数据...

 

二级参考文献:

正在载入数据...

 

耦合文献:

正在载入数据...

 

引证文献:

正在载入数据...

 

二级引证文献:

正在载入数据...

 

同被引文献:

正在载入数据...

 

相关期刊文献:

正在载入数据...

相关的主题
相关的作者对象
相关的机构对象