检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:Hirotake Yo Hirotsugu Ohashi Ryo Sugama Tessyu Ikawa Hirotake Yo;Hirotsugu Ohashi;Ryo Sugama;Tessyu Ikawa(Department of Orthopaedic Surgery, Osaka Saiseikai Nakatsu Hospital, Osaka, Japan)
机构地区:[1]Department of Orthopaedic Surgery, Osaka Saiseikai Nakatsu Hospital, Osaka, Japan
出 处:《Open Journal of Orthopedics》2016年第2期23-28,共6页矫形学期刊(英文)
摘 要:Direct anterior approach (DAA) for total hip arthroplasty (THA) is a minimally invasive technique. In this approach, two assistants are necessary. We developed a retractor holding device called “Spider arm” to replace an assistant in the contra-lateral side. In this study, we investigated the usefulness of Spider arm in THA through direct anterior approach. 20 hips were operated without Spider arm and 21 hips were operated with Spider arm. The surgery time and the blood loss were compared. The cup position and leg length discrepancy were measured on radiography. There was no statistical significance between two groups in all parameters. No clinical complications were reported. With Spider arm, DAA-THA could be performed by two surgeons without deterioration of the surgery time and blood loss. The accuracy of cup position and leg length discrepancy was not affected. Spider arm can contribute to reducing the manpower in DAA-THA.Direct anterior approach (DAA) for total hip arthroplasty (THA) is a minimally invasive technique. In this approach, two assistants are necessary. We developed a retractor holding device called “Spider arm” to replace an assistant in the contra-lateral side. In this study, we investigated the usefulness of Spider arm in THA through direct anterior approach. 20 hips were operated without Spider arm and 21 hips were operated with Spider arm. The surgery time and the blood loss were compared. The cup position and leg length discrepancy were measured on radiography. There was no statistical significance between two groups in all parameters. No clinical complications were reported. With Spider arm, DAA-THA could be performed by two surgeons without deterioration of the surgery time and blood loss. The accuracy of cup position and leg length discrepancy was not affected. Spider arm can contribute to reducing the manpower in DAA-THA.
关 键 词:Retractor Holding Device Spider Arm Direct Anterior Approach Hip Arthroplasty
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在链接到云南高校图书馆文献保障联盟下载...
云南高校图书馆联盟文献共享服务平台 版权所有©
您的IP:216.73.216.151