Pressure Measurements from Five Different Nosebands at Rest, and During Riding at Walk, a Collected Gait, Backing up and a Full Stop  

Pressure Measurements from Five Different Nosebands at Rest, and During Riding at Walk, a Collected Gait, Backing up and a Full Stop

在线阅读下载全文

作  者:Adrian Harrison Adrian Harrison(Dept for Veterinary and Animal Sciences (IVH), Faculty of Health & Medical Sciences, University of Copenhagen, PAS, Section for Physiology, Frederiksberg, Denmark)

机构地区:[1]Dept for Veterinary and Animal Sciences (IVH), Faculty of Health & Medical Sciences, University of Copenhagen, PAS, Section for Physiology, Frederiksberg, Denmark

出  处:《Open Journal of Veterinary Medicine》2024年第6期137-154,共18页兽医学(英文)

摘  要:Background: Scientific procedures for addressing noseband fit and tightness, eliminating the risk of excessive and painful tightening, as well as quantitative measurements of pressures under the noseband while riding are either scarce or lacking. Purpose/Aim: To assess simple means of measuring pressure under different nosebands with a view to their adoption as scientific methodology. Method: Horses (n = 7) were fitted with five different bridles (A-E). Pressure distribution and intensity were measured using colour sensitive film (Fujifilm LLLW), assessing the level of pressure and distribution across the surface of the nosebands, as assessed and ranked by independent assessors. A CURO system was also used to measure pressure in real-time under nosebands whilst riding. Results: The colour-sensitive film for D & B were ranked 1st and 2nd, respectively. Regularity of pressure overall showed a statistical difference between nosebands (A & B significantly more unregular than the others). Pressure measurements revealed significantly different means (all P Conclusions: Pressures under nosebands can reach levels that appear capable of inflicting tissue damage, hence bridles and nosebands should be assessed using scientific methodology and not based on arbitrary and subjective criteria, as is currently the case.Background: Scientific procedures for addressing noseband fit and tightness, eliminating the risk of excessive and painful tightening, as well as quantitative measurements of pressures under the noseband while riding are either scarce or lacking. Purpose/Aim: To assess simple means of measuring pressure under different nosebands with a view to their adoption as scientific methodology. Method: Horses (n = 7) were fitted with five different bridles (A-E). Pressure distribution and intensity were measured using colour sensitive film (Fujifilm LLLW), assessing the level of pressure and distribution across the surface of the nosebands, as assessed and ranked by independent assessors. A CURO system was also used to measure pressure in real-time under nosebands whilst riding. Results: The colour-sensitive film for D & B were ranked 1st and 2nd, respectively. Regularity of pressure overall showed a statistical difference between nosebands (A & B significantly more unregular than the others). Pressure measurements revealed significantly different means (all P Conclusions: Pressures under nosebands can reach levels that appear capable of inflicting tissue damage, hence bridles and nosebands should be assessed using scientific methodology and not based on arbitrary and subjective criteria, as is currently the case.

关 键 词:Noseband WELFARE Pain Bridle Fit Riding Tölt FEI 

分 类 号:TL9[核科学技术]

 

参考文献:

正在载入数据...

 

二级参考文献:

正在载入数据...

 

耦合文献:

正在载入数据...

 

引证文献:

正在载入数据...

 

二级引证文献:

正在载入数据...

 

同被引文献:

正在载入数据...

 

相关期刊文献:

正在载入数据...

相关的主题
相关的作者对象
相关的机构对象