Safety and Performance of Sirolimus-Eluting Coronary Stent System with Biodegradable Polymer: A Retrospective Analysis in Real-World Patient Population  被引量:1

Safety and Performance of Sirolimus-Eluting Coronary Stent System with Biodegradable Polymer: A Retrospective Analysis in Real-World Patient Population

在线阅读下载全文

作  者:Vithala Surya Prakasa Rao A. S. V. Narayana Rao Pannala Lakshmi Narasimha Kapardhi Priyen Kantilal Shah Revanur Viswanath Satyajit Govindrao Mehetre Avanindra Kumar Srivastava 

机构地区:[1]Department of Cardiology, Apollo Hospitals, Hyderabad, India

出  处:《World Journal of Cardiovascular Diseases》2017年第5期163-173,共11页心血管病(英文)

摘  要:Background and Aim: Newer generation coronary stent systems with low profile metallic frame, biodegradable polymer coating and potent but safe anti-restenosis drug from “limus family” are emerging as safe and effective stents. To evaluate the safety and performance of Metafor SES (Meril life Sciences Pvt. Ltd., Vapi, India) in consecutive patients in a real-world population. Methods: The study was a retrospective, non-randomized, single-center study which evaluated the data of 127 patients who underwent percutaneous coronary intervention (PCI) treated with Metafor SES from February 2012 to February 2015 and mean follow-up period of those patients was 3.6 ± 0.6 years. The primary endpoint was a major adverse cardiac event (MACE) including cardiac death, myocardial infarction (MI), and target lesion revascularization (TLR). In addition, Stent thrombosis (ST) was analyzed at respective follow-up period. Results: A total of 127 patients (mean age: 53.70 ± 8.41 years and 99 males) were included. Among those 80 (63%) patients had hypertension and 58 (45.7%) patients with diabetes mellitus.At follow-up, MACE in form of TLR was observed in 2 (1.6%) patients only. No cardiac death or stent thrombosis was reported in any patient. A total of 169 lesions were treated with the Metafor SES (1.3 stents per lesion). The 38.4% of patients treated with the Metafor SES with lesion length ≥24 mm, and the procedural success was 100%. Conclusions: The lower incidence of MACE in uncontrolled and real world population at long term follow-up clearly depicts the prolonged safety and performance of the Metafor SES.Background and Aim: Newer generation coronary stent systems with low profile metallic frame, biodegradable polymer coating and potent but safe anti-restenosis drug from “limus family” are emerging as safe and effective stents. To evaluate the safety and performance of Metafor SES (Meril life Sciences Pvt. Ltd., Vapi, India) in consecutive patients in a real-world population. Methods: The study was a retrospective, non-randomized, single-center study which evaluated the data of 127 patients who underwent percutaneous coronary intervention (PCI) treated with Metafor SES from February 2012 to February 2015 and mean follow-up period of those patients was 3.6 ± 0.6 years. The primary endpoint was a major adverse cardiac event (MACE) including cardiac death, myocardial infarction (MI), and target lesion revascularization (TLR). In addition, Stent thrombosis (ST) was analyzed at respective follow-up period. Results: A total of 127 patients (mean age: 53.70 ± 8.41 years and 99 males) were included. Among those 80 (63%) patients had hypertension and 58 (45.7%) patients with diabetes mellitus.At follow-up, MACE in form of TLR was observed in 2 (1.6%) patients only. No cardiac death or stent thrombosis was reported in any patient. A total of 169 lesions were treated with the Metafor SES (1.3 stents per lesion). The 38.4% of patients treated with the Metafor SES with lesion length ≥24 mm, and the procedural success was 100%. Conclusions: The lower incidence of MACE in uncontrolled and real world population at long term follow-up clearly depicts the prolonged safety and performance of the Metafor SES.

关 键 词:BIODEGRADABLE Polymer Cobalt-Chromium Metafor SES Sirolimus-Eluting STENT STENT THROMBOSIS 

分 类 号:R5[医药卫生—内科学]

 

参考文献:

正在载入数据...

 

二级参考文献:

正在载入数据...

 

耦合文献:

正在载入数据...

 

引证文献:

正在载入数据...

 

二级引证文献:

正在载入数据...

 

同被引文献:

正在载入数据...

 

相关期刊文献:

正在载入数据...

相关的主题
相关的作者对象
相关的机构对象