Recurrent Stroke after Percutaneous Placement of Post-Infarct Septal Occluder Device  

Recurrent Stroke after Percutaneous Placement of Post-Infarct Septal Occluder Device

在线阅读下载全文

作  者:Suguru Ohira B. S. Matan Grunfeld Amanda Hetzel Rohinton J. Morris Suguru Ohira;B. S. Matan Grunfeld;Amanda Hetzel;Rohinton J. Morris(Division of Cardiothoracic Surgery, Department of Surgery, Westchester Medical Center, New York Medical College, Valhalla, NY, USA;Division of Cardiac Surgery, Department of Surgery, Thomas Jefferson University Hospital, Philadelphia, PA, USA)

机构地区:[1]Division of Cardiothoracic Surgery, Department of Surgery, Westchester Medical Center, New York Medical College, Valhalla, NY, USA [2]Division of Cardiac Surgery, Department of Surgery, Thomas Jefferson University Hospital, Philadelphia, PA, USA

出  处:《World Journal of Cardiovascular Surgery》2022年第9期191-195,共5页心血管外科国际期刊(英文)

摘  要:Surgical intervention for post-infarct ventricular septal defect (VSD) is a challenging procedure due to patients’ complex preoperative conditions. While percutaneous VSD closure can be considered as an alternative to surgical repair, complete closure of the defect remains difficult and is associated with various procedural complications. We report a rare case of a patient with postoperative residual shunts who experienced recurrent stroke episodes, requiring surgical intervention for repair. The patient, a 71-year-old female, developed acute anterior myocardial infarction and post-infarct VSD. Percutaneous closure with a 14-mm Amplatzer VSD occluder device was performed, yet the closure was incomplete. Following discharge, she developed multiple embolic stroke episodes, likely stemming from the residual VSD, which led to the surgical extraction of the device and VSD repair. Fibrous tissue was found to be solely attached to the core and right ventricle side of the device, whilst no fibrous tissue was observed on the side of the left ventricle. The patient has not experienced new neurological symptoms at an 18-month follow-up. Thus, it is paramount to keep in mind that an embolic stroke may occur in the setting of percutaneous post-infarct VSD closure. Surgical repair of VSD with device removal should be considered as a treatment option to such a complex case.Surgical intervention for post-infarct ventricular septal defect (VSD) is a challenging procedure due to patients’ complex preoperative conditions. While percutaneous VSD closure can be considered as an alternative to surgical repair, complete closure of the defect remains difficult and is associated with various procedural complications. We report a rare case of a patient with postoperative residual shunts who experienced recurrent stroke episodes, requiring surgical intervention for repair. The patient, a 71-year-old female, developed acute anterior myocardial infarction and post-infarct VSD. Percutaneous closure with a 14-mm Amplatzer VSD occluder device was performed, yet the closure was incomplete. Following discharge, she developed multiple embolic stroke episodes, likely stemming from the residual VSD, which led to the surgical extraction of the device and VSD repair. Fibrous tissue was found to be solely attached to the core and right ventricle side of the device, whilst no fibrous tissue was observed on the side of the left ventricle. The patient has not experienced new neurological symptoms at an 18-month follow-up. Thus, it is paramount to keep in mind that an embolic stroke may occur in the setting of percutaneous post-infarct VSD closure. Surgical repair of VSD with device removal should be considered as a treatment option to such a complex case.

关 键 词:Ischemic Heart Disease Post-Infarct Ventricular Septal Defect Percutaneous Closure 

分 类 号:R54[医药卫生—心血管疾病]

 