An Investigation of Power Converters Fed BLDC Motor for Adjustable Speed  被引量:1

An Investigation of Power Converters Fed BLDC Motor for Adjustable Speed

在线阅读下载全文

作  者:Subramaniam Kaliappan Dr. Ramachandran Rajeswari Subramaniam Kaliappan;Dr. Ramachandran Rajeswari(Department of Electrical and Electronics Engineering, Kumaraguru College of Technology, Coimbatore, India;Department of Electrical and Electronics Engineering, Government College of Technology, Coimbatore, India)

机构地区:[1]Department of Electrical and Electronics Engineering, Kumaraguru College of Technology, Coimbatore, India [2]Department of Electrical and Electronics Engineering, Government College of Technology, Coimbatore, India

出  处:《Circuits and Systems》2016年第8期1369-1378,共10页电路与系统(英文)

摘  要:This paper reports the converter topologies which are employed for better Power Factor Correction at the input side. The Power Factor Correction is an important factor when considering the Power Quality. Based on the converter topologies, the Bridgeless converters are preferred in order to reduce the number of switching devices, losses associated with it and improve the Power Quality further more. This paper investigates about the Power Factor performances and conduction losses of the Bridgeless Power Factor Corrector Converters which see through the benefits and limitations by analyzing the Bridgeless Buck-Boost Converter, Bridgeless SEPIC converter and Bridgeless CUK converter. The resultant voltage is fed to the BLDC motor which is rapidly replacing the Induction motor for its better operating characteristics. These strategies are being analyzed using the MATLAB/Simulink software and the results are verified through the experimental analysis. The converter choice is preferred through the performance characteristics and Power Factor Correction at the supply. The Power Factor obtained should be within the acceptable limits under IEC 61000-3-2 standards.This paper reports the converter topologies which are employed for better Power Factor Correction at the input side. The Power Factor Correction is an important factor when considering the Power Quality. Based on the converter topologies, the Bridgeless converters are preferred in order to reduce the number of switching devices, losses associated with it and improve the Power Quality further more. This paper investigates about the Power Factor performances and conduction losses of the Bridgeless Power Factor Corrector Converters which see through the benefits and limitations by analyzing the Bridgeless Buck-Boost Converter, Bridgeless SEPIC converter and Bridgeless CUK converter. The resultant voltage is fed to the BLDC motor which is rapidly replacing the Induction motor for its better operating characteristics. These strategies are being analyzed using the MATLAB/Simulink software and the results are verified through the experimental analysis. The converter choice is preferred through the performance characteristics and Power Factor Correction at the supply. The Power Factor obtained should be within the acceptable limits under IEC 61000-3-2 standards.

关 键 词:BLDC Motor Power Factor Correction Power Quality PFC Converters 

分 类 号:TM4[电气工程—电器]

 