A Natural Catalytic Converter® for Continuously Inactivating Air and Surface Pathogens with More Effect than Ventilation and Filtration  

A Natural Catalytic Converter® for Continuously Inactivating Air and Surface Pathogens with More Effect than Ventilation and Filtration

在线阅读下载全文

作  者:Margaret Scarlett Brett Duffy Margaret Scarlett;Brett Duffy(CAPT. (Ret.), US Public Health Service, Centers for Disease Control and Prevention, Atlanta, GA, United States of America;ASHRAE (62.1 Standard Committee), Atlanta, GA, United States of America)

机构地区:[1]CAPT. (Ret.), US Public Health Service, Centers for Disease Control and Prevention, Atlanta, GA, United States of America [2]ASHRAE (62.1 Standard Committee), Atlanta, GA, United States of America

出  处:《Open Journal of Applied Sciences》2024年第5期1353-1363,共11页应用科学(英文)

摘  要:Study Objective: The purpose of the study is to present independent laboratory testing for a novel technology in air and on surfaces. Since 2020, public health goals have focused on improving indoor air quality. This includes protection from airborne pathogens, such as tuberculosis, RSV, SARS-CoV-2, common cold or influenza viruses, measles, and others. Engineering controls are highly effective at reducing hazardous pathogens found in indoor air and from recontamination of surfaces. This occurs from a continuous cycle of settling of small, sustained airborne pathogens, which may become dehumidified, becoming airborne again, carried by room air currents around indoor spaces, then repeating the cycle. Methods: The novel technology utilizes a catalytic process to produce safe levels of hydrogen peroxide gas that are effective in reducing pathogens in the air and on surfaces. Air testing was performed with the MS2 bacteriophage, the test organism for ASHRAE standard 241, and methicillin-Resistant Staphylococcus aureus (MRSA). Surface testing was performed with SARS-COV-2 (Coronavirus COVID-19) and H1N1 (Influenza). Typical ventilation and filtration does not effectively remove disbursed pathogens from the entire facility, due to inconsistent air circulation and surface deposits of pathogens. Results: MS2 was reduced by 99.9%;MRSA was reduced by 99.9%;SARS-CoV-2 was reduced by 99.9%;H1N1 was reduced by 99.9%. Conclusion: This novel catalytic converter reduces a variety of pathogens in the air (99%) and on surfaces (99%), by actively disinfecting with the introduction of gaseous hydrogen peroxide. This active disinfection provides a strong solution for protecting the entire facility and its occupants.Study Objective: The purpose of the study is to present independent laboratory testing for a novel technology in air and on surfaces. Since 2020, public health goals have focused on improving indoor air quality. This includes protection from airborne pathogens, such as tuberculosis, RSV, SARS-CoV-2, common cold or influenza viruses, measles, and others. Engineering controls are highly effective at reducing hazardous pathogens found in indoor air and from recontamination of surfaces. This occurs from a continuous cycle of settling of small, sustained airborne pathogens, which may become dehumidified, becoming airborne again, carried by room air currents around indoor spaces, then repeating the cycle. Methods: The novel technology utilizes a catalytic process to produce safe levels of hydrogen peroxide gas that are effective in reducing pathogens in the air and on surfaces. Air testing was performed with the MS2 bacteriophage, the test organism for ASHRAE standard 241, and methicillin-Resistant Staphylococcus aureus (MRSA). Surface testing was performed with SARS-COV-2 (Coronavirus COVID-19) and H1N1 (Influenza). Typical ventilation and filtration does not effectively remove disbursed pathogens from the entire facility, due to inconsistent air circulation and surface deposits of pathogens. Results: MS2 was reduced by 99.9%;MRSA was reduced by 99.9%;SARS-CoV-2 was reduced by 99.9%;H1N1 was reduced by 99.9%. Conclusion: This novel catalytic converter reduces a variety of pathogens in the air (99%) and on surfaces (99%), by actively disinfecting with the introduction of gaseous hydrogen peroxide. This active disinfection provides a strong solution for protecting the entire facility and its occupants.

关 键 词:PATHOGEN Bacteria Virus Reduction Gaseous Hydrogen Peroxide DISINFECTION Indoor Air Quality SURFACE 