Diagnostic Reference Levels for Adult Patients Undergoing Cranioencephalic and Abdominal Pelvic CT-Scans at the University Hospital of Treichville in Côte d’Ivoire  

Diagnostic Reference Levels for Adult Patients Undergoing Cranioencephalic and Abdominal Pelvic CT-Scans at the University Hospital of Treichville in Côte d’Ivoire

在线阅读下载全文

作  者:Issa Konaté Koutoua Joseph Anouan Aka Antonin Koua Vas Souleymane Bakayoko Issa Konaté;Koutoua Joseph Anouan;Aka Antonin Koua;Vas Souleymane Bakayoko(Nuclear Physics and Radiation Protection Team, Training and Research Unit-Sciences of the Structures of Matter and Technology, University Flix Houphout-Boigny of Abidjan, Abidjan, Cte dIvoire;Direction des tablissements privs et des Professions Sanitaires (DEPPS) du Ministre Ivoirien de la Sant, Abidjan, Cte dIvoire)

机构地区:[1]Nuclear Physics and Radiation Protection Team, Training and Research Unit-Sciences of the Structures of Matter and Technology, University Flix Houphout-Boigny of Abidjan, Abidjan, Cte dIvoire [2]Direction des tablissements privs et des Professions Sanitaires (DEPPS) du Ministre Ivoirien de la Sant, Abidjan, Cte dIvoire

出  处:《Open Journal of Applied Sciences》2024年第12期3556-3561,共6页应用科学(英文)

摘  要:Objectives: To investigate the dose delivered to adult patients during cranioencephalic and abdominal-pelvic examinations in computed tomography (CT) in order to set up the Local Dosimetric Reference Levels (LDRLs) of the University Hospital of Treichville (UHT) for the radiation protection of patients undergoing CT scans. Methods: This study was prospectively performed on 153 CT images of adult patients including 120 CT images of cranioencephalic (CE) and 33 CT images of the abdominal pelvic (AP) examinations. These images were acquired on the CT system INSITUM with 64 bars, manufactured by the company SINOVISION and commissioned in 2021 at UHT. Then the volume computed tomography index (CTDIvol) and the dose-length product (DLP) were determined. Results: Based on the statistical method of 75th percentile, the obtained LDRLs as CTDIvol and DLP are 54.37 mGy and 28.07 mGy, 1716 mGy.cm and 1490.8 mGy.cm respectively for CE and AP examinations. Comparing our results with those from different international studies, CTDIvol and DLP values obtained in the present work are higher. Conclusion: LDRLs for dosimetric quantities such as CTDIvol and DLP for CE and AP examinations have been set up in this study. It will contribute with further studies to the national diagnostic reference levels of cranioencephalic and abdominal pelvis CT exams for strengthening the radiation protection of patients in Côte d’Ivoire.Objectives: To investigate the dose delivered to adult patients during cranioencephalic and abdominal-pelvic examinations in computed tomography (CT) in order to set up the Local Dosimetric Reference Levels (LDRLs) of the University Hospital of Treichville (UHT) for the radiation protection of patients undergoing CT scans. Methods: This study was prospectively performed on 153 CT images of adult patients including 120 CT images of cranioencephalic (CE) and 33 CT images of the abdominal pelvic (AP) examinations. These images were acquired on the CT system INSITUM with 64 bars, manufactured by the company SINOVISION and commissioned in 2021 at UHT. Then the volume computed tomography index (CTDIvol) and the dose-length product (DLP) were determined. Results: Based on the statistical method of 75th percentile, the obtained LDRLs as CTDIvol and DLP are 54.37 mGy and 28.07 mGy, 1716 mGy.cm and 1490.8 mGy.cm respectively for CE and AP examinations. Comparing our results with those from different international studies, CTDIvol and DLP values obtained in the present work are higher. Conclusion: LDRLs for dosimetric quantities such as CTDIvol and DLP for CE and AP examinations have been set up in this study. It will contribute with further studies to the national diagnostic reference levels of cranioencephalic and abdominal pelvis CT exams for strengthening the radiation protection of patients in Côte d’Ivoire.

关 键 词:Computed Tomography Cranioencephalic Abdominal Pelvic Radiation Protection Diagnostic Reference Levels 

分 类 号:R81[医药卫生—放射医学]

 