Assessment of the Microbiological Quality of Drinking Water from Some Wells and Boreholes in the City of Abeche (Chad)  

Assessment of the Microbiological Quality of Drinking Water from Some Wells and Boreholes in the City of Abeche (Chad)

在线阅读下载全文

作  者:Mablahi Amina Kanika Imar Djibrine Soudy Alhadj Markhous Nazal Oumalkher Youssouf Adam Yacoub Mahamat Allamine Akoïna Moursal Mablahi Amina Kanika;Imar Djibrine Soudy;Alhadj Markhous Nazal;Oumalkher Youssouf Adam;Yacoub Mahamat Allamine;Akoïna Moursal(Ministry of Public Health and Prevention (Chad), NDjamena, Chad;Food Sciences and Nutrition Research Laboratory, Faculty of Human Health Sciences (FSSH), University of NDjamena, NDjamena, Chad;Food Quality Control Centre (CECOQDA), NDjamena, Chad;Faculty of Agriculture and Environmental Sciences, University of Sarh, Chad;National Water Laboratory, Ministry of Water and Energy, NDjamena, Chad)

机构地区:[1]Ministry of Public Health and Prevention (Chad), NDjamena, Chad [2]Food Sciences and Nutrition Research Laboratory, Faculty of Human Health Sciences (FSSH), University of NDjamena, NDjamena, Chad [3]Food Quality Control Centre (CECOQDA), NDjamena, Chad [4]Faculty of Agriculture and Environmental Sciences, University of Sarh, Chad [5]National Water Laboratory, Ministry of Water and Energy, NDjamena, Chad

出  处:《Food and Nutrition Sciences》2024年第12期1253-1263,共11页食品与营养科学(英文)

摘  要:The inadequacy of drinking water distribution by the Chadian Water Company (STE) has led to the proliferation of private wells and boreholes in the city of Abéché. This study aims to evaluate the microbiological quality of the drinking water from these wells and boreholes in the city. Methodology: To carry out this study, a randomized selection of forty-five (45) water points, including nine (9) wells and thirty-six (36) boreholes, was identified, and samples were collected. These samples were sent to the National Water Laboratory (LNE) to test for several microbiological parameters, namely Escherichia coli, total coliforms, fecal coliforms, fecal enterococci, and total aerobic flora. The technique used for this analysis was spread plating and membrane filtration. Results: The average values obtained in the well water are 0.338*104 CFU/100 ml for total coliforms, 0.156*104 CFU/100 ml for fecal coliforms, 0.319*103 CFU/100 ml for Escherichia coli, 33.33 CFU/100 ml for fecal enterococci and 1.385*104 CFU/100 ml for total aerobic flora. For borehole water, the average values obtained are 0.469*104 CFU/100 ml for total coliforms, 0.134*104 CFU/100 ml for fecal coliforms, 0.337*103 CFU/100 ml for Escherichia coli, 16.67 CFU/100 ml for fecal enterococci and 1.47*104 CFU/100 ml for total aerobic flora. Conclusion: According to the tolerance thresholds set by the WHO, the average values obtained significantly exceed the recommended standards for drinking water. Therefore, these waters must be treated alongside environmental sanitation measures at water points to ensure a safe drinking water supply that poses no major health risks to the population. For this fact, an appropriate health survey and the implementation of community water and sanitation projects are recommended.The inadequacy of drinking water distribution by the Chadian Water Company (STE) has led to the proliferation of private wells and boreholes in the city of Abéché. This study aims to evaluate the microbiological quality of the drinking water from these wells and boreholes in the city. Methodology: To carry out this study, a randomized selection of forty-five (45) water points, including nine (9) wells and thirty-six (36) boreholes, was identified, and samples were collected. These samples were sent to the National Water Laboratory (LNE) to test for several microbiological parameters, namely Escherichia coli, total coliforms, fecal coliforms, fecal enterococci, and total aerobic flora. The technique used for this analysis was spread plating and membrane filtration. Results: The average values obtained in the well water are 0.338*104 CFU/100 ml for total coliforms, 0.156*104 CFU/100 ml for fecal coliforms, 0.319*103 CFU/100 ml for Escherichia coli, 33.33 CFU/100 ml for fecal enterococci and 1.385*104 CFU/100 ml for total aerobic flora. For borehole water, the average values obtained are 0.469*104 CFU/100 ml for total coliforms, 0.134*104 CFU/100 ml for fecal coliforms, 0.337*103 CFU/100 ml for Escherichia coli, 16.67 CFU/100 ml for fecal enterococci and 1.47*104 CFU/100 ml for total aerobic flora. Conclusion: According to the tolerance thresholds set by the WHO, the average values obtained significantly exceed the recommended standards for drinking water. Therefore, these waters must be treated alongside environmental sanitation measures at water points to ensure a safe drinking water supply that poses no major health risks to the population. For this fact, an appropriate health survey and the implementation of community water and sanitation projects are recommended.

关 键 词:Microbiological Quality Water BOREHOLES WELLS Abeche-Chad 

分 类 号:F42[经济管理—产业经济]

 

参考文献:

正在载入数据...

 

二级参考文献:

正在载入数据...

 

耦合文献:

正在载入数据...

 

引证文献:

正在载入数据...

 

二级引证文献:

正在载入数据...

 

同被引文献:

正在载入数据...

 

相关期刊文献:

正在载入数据...

相关的主题
相关的作者对象
相关的机构对象