检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:Marina Arad Avraham Adunsky Sharon Zlochiver Ofer Barnea Shimon Abboud
机构地区:[1]不详
出 处:《Journal of Biomedical Science and Engineering》2011年第1期76-81,共6页生物医学工程(英文)
摘 要:Regular monitoring of pulmonary congestion in car-diogenic pulmonary edema (CPE) patients is neces-sary for its adequate management via pharmaceuti-cal treatment. It is well known that the development of CPE is accompanied with an increase in hema-tocrit, plasma protein concentration and colloid os-motic pressure due to the decrease in the plasma volume. In the present study the mean left and right lung resistivity values taken pre- and post treatment with diuretics using a hybrid bio-impedance electri-cal impedance tomography system were correlate to the measured changes in hematocrit level. A marginal significant correlation was found between the abso-lute mean lung resistivity and hematocrit levels (Pearson’s correlation coefficient of R = 0.4, p-value = 0.057). When the change in the mean lung resistivity of a patient was plotted vs. the change in hematocrit readout, a significant linear correlation was found (R = 0.7, p-value = 0.02). These results support the validity of the resistivity measurements using bio-impedance system in monitoring changes of pulmonary edema in CPE patients.Regular monitoring of pulmonary congestion in car-diogenic pulmonary edema (CPE) patients is neces-sary for its adequate management via pharmaceuti-cal treatment. It is well known that the development of CPE is accompanied with an increase in hema-tocrit, plasma protein concentration and colloid os-motic pressure due to the decrease in the plasma volume. In the present study the mean left and right lung resistivity values taken pre- and post treatment with diuretics using a hybrid bio-impedance electri-cal impedance tomography system were correlate to the measured changes in hematocrit level. A marginal significant correlation was found between the abso-lute mean lung resistivity and hematocrit levels (Pearson’s correlation coefficient of R = 0.4, p-value = 0.057). When the change in the mean lung resistivity of a patient was plotted vs. the change in hematocrit readout, a significant linear correlation was found (R = 0.7, p-value = 0.02). These results support the validity of the resistivity measurements using bio-impedance system in monitoring changes of pulmonary edema in CPE patients.
关 键 词:BIO-IMPEDANCE Parametric EIT CARDIOGENIC Pulmonary EDEMA HEMATOCRIT
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在链接到云南高校图书馆文献保障联盟下载...
云南高校图书馆联盟文献共享服务平台 版权所有©
您的IP:216.73.216.222