Biomechanical comparison of distal locking screws for distal tibia fracture intramedullary nailing  被引量:1

Biomechanical comparison of distal locking screws for distal tibia fracture intramedullary nailing

在线阅读下载全文

作  者:Brennen L. Lucas Alexander C.M. Chong Bruce R. Buhr Teresa L. Jones Paul H. Wooley 

机构地区:[1]不详

出  处:《Journal of Biomedical Science and Engineering》2011年第4期235-241,共7页生物医学工程(英文)

摘  要:Background: Newer generation intramedullary (IM) tibial nails provide several distal interlocking screw options. The objectives were to determine: 1) if the new oblique interlocking option provides superior stability, 2) which screw orientation/ configuration is the most biomechanically stable, and 3) if three distal interlocking screws provide better stability. Methods: A preliminary experiment was performed in torsion, compression, and bending tests with four different screw configurations: (I) one medial-to-lateral and one oblique, (II) two me-dial-to-lateral, (III) one medial-to-lateral and one anterior-to-posterior, and (IV) one medial-to-lateral, one anterior-to-posterior and one oblique in simu-lated distal metaphyseal fracture tibiae. Twenty- four Synthes EXPERT tibial IM nails were used for six specimens of each screw configuration. Parts I and II, tibial IM nails were locked with 5.0 mm in-terlocking screws into simulated distal tibiae (PVC and composite analogue tibia). Part III, the two most stable configurations were tested using five pairs of simulated cadaveric distal tibiae metaphy-seal fractures. Results: Significant differences were attributable to distal screw orientation for intrame- dullary nailing of distal tibia fractures. Configura-tions II and IV were found to be more stable than the other two configurations. No significant differ-ence was detected in construct stability in all modes of testing between Configurations II and IV. Dis-cussion: Configuration I did not provide superior stability for the distal tibia fracture fixation. Con-figurations II and IV provided equivalent stability. When choosing IM fixation for treatment of distal tibia metaphyseal fractures two medial-to-lateral screws provide the necessary stability for satisfac-tory fixation. Clinical Relevance: This study indi-cated an option for operative treatment of distal metaphyseal tibia fracture fixation where preserva-tion of soft tissue and rigid stabilization are needed.Background: Newer generation intramedullary (IM) tibial nails provide several distal interlocking screw options. The objectives were to determine: 1) if the new oblique interlocking option provides superior stability, 2) which screw orientation/ configuration is the most biomechanically stable, and 3) if three distal interlocking screws provide better stability. Methods: A preliminary experiment was performed in torsion, compression, and bending tests with four different screw configurations: (I) one medial-to-lateral and one oblique, (II) two me-dial-to-lateral, (III) one medial-to-lateral and one anterior-to-posterior, and (IV) one medial-to-lateral, one anterior-to-posterior and one oblique in simu-lated distal metaphyseal fracture tibiae. Twenty- four Synthes EXPERT tibial IM nails were used for six specimens of each screw configuration. Parts I and II, tibial IM nails were locked with 5.0 mm in-terlocking screws into simulated distal tibiae (PVC and composite analogue tibia). Part III, the two most stable configurations were tested using five pairs of simulated cadaveric distal tibiae metaphy-seal fractures. Results: Significant differences were attributable to distal screw orientation for intrame- dullary nailing of distal tibia fractures. Configura-tions II and IV were found to be more stable than the other two configurations. No significant differ-ence was detected in construct stability in all modes of testing between Configurations II and IV. Dis-cussion: Configuration I did not provide superior stability for the distal tibia fracture fixation. Con-figurations II and IV provided equivalent stability. When choosing IM fixation for treatment of distal tibia metaphyseal fractures two medial-to-lateral screws provide the necessary stability for satisfac-tory fixation. Clinical Relevance: This study indi-cated an option for operative treatment of distal metaphyseal tibia fracture fixation where preserva-tion of soft tissue and rigid stabilization are needed.

关 键 词:BIOMECHANICAL LOCKING Screws INTRAMEDULLARY NAIL DISTAL TIBIA 

分 类 号:R6[医药卫生—外科学]

 

参考文献:

正在载入数据...

 

二级参考文献:

正在载入数据...

 

耦合文献:

正在载入数据...

 

引证文献:

正在载入数据...

 

二级引证文献:

正在载入数据...

 

同被引文献:

正在载入数据...

 

相关期刊文献:

正在载入数据...

相关的主题
相关的作者对象
相关的机构对象