Assessment of Non-Contact Measurement Using a Microwave Sensor to Jugular Venous Pulse Monitoring  

Assessment of Non-Contact Measurement Using a Microwave Sensor to Jugular Venous Pulse Monitoring

在线阅读下载全文

作  者:Satoshi Suzuki Masaaki Hoshiga Kentaro Kotani Takafumi Asao Satoshi Suzuki;Masaaki Hoshiga;Kentaro Kotani;Takafumi Asao(Faculty of Engineering Science, Kansai University, Osaka, Japan;Faculty of Medicine, Osaka Medical College, Osaka, Japan)

机构地区:[1]Faculty of Engineering Science, Kansai University, Osaka, Japan [2]Faculty of Medicine, Osaka Medical College, Osaka, Japan

出  处:《Journal of Biomedical Science and Engineering》2021年第3期94-102,共9页生物医学工程(英文)

摘  要:The jugular venous pulse (JVP) waveform provides an insight into right heart function, and its assessment is important in patients with heart failure. However, the conventional pulse-transducer (contact) method for monitoring this waveform is not frequently used because it requires a high degree of skill. The aim of this study was to confirm the effectiveness of a prototype non-contact system that employs microwave radar (24 GHz, 7 mW;non-contact system) for JVP measurement. Experiments were conducted on eight healthy male volunteers (21.88 ± 0.99 years). JVP measurements were compared between the conventional contact method and the proposed non-contact method. Change in JVP waveform was measured in response to an angle of reclining in five steps from the supine position to 75<span style="white-space:nowrap;">°</span> of elevation. The obtained JVP measurements were similar between the two methods. Because in the non-contact method the faint pulsation of the JVP is not suppressed by the pressure of a sensor placed on the skin, the prototype microwave radar system is particularly suitable for evaluating the JVP waveform.The jugular venous pulse (JVP) waveform provides an insight into right heart function, and its assessment is important in patients with heart failure. However, the conventional pulse-transducer (contact) method for monitoring this waveform is not frequently used because it requires a high degree of skill. The aim of this study was to confirm the effectiveness of a prototype non-contact system that employs microwave radar (24 GHz, 7 mW;non-contact system) for JVP measurement. Experiments were conducted on eight healthy male volunteers (21.88 ± 0.99 years). JVP measurements were compared between the conventional contact method and the proposed non-contact method. Change in JVP waveform was measured in response to an angle of reclining in five steps from the supine position to 75<span style="white-space:nowrap;">°</span> of elevation. The obtained JVP measurements were similar between the two methods. Because in the non-contact method the faint pulsation of the JVP is not suppressed by the pressure of a sensor placed on the skin, the prototype microwave radar system is particularly suitable for evaluating the JVP waveform.

关 键 词:Microwave Radar Non-Contact Monitoring Jugular Venous Pressure Right Heart Function 

分 类 号:TN9[电子电信—信息与通信工程]

 

参考文献:

正在载入数据...

 

二级参考文献:

正在载入数据...

 

耦合文献:

正在载入数据...

 

引证文献:

正在载入数据...

 

二级引证文献:

正在载入数据...

 

同被引文献:

正在载入数据...

 

相关期刊文献:

正在载入数据...

相关的主题
相关的作者对象
相关的机构对象