Factors Influence on the Broaching Hammering Sound during Cementless Total Hip Arthroplasty  被引量:1

Factors Influence on the Broaching Hammering Sound during Cementless Total Hip Arthroplasty

在线阅读下载全文

作  者:Xu Zhuang Yasuhiro Homma Taichi Sato Tomonori Baba Itaru Morohashi Hideaki Iwase Kazuo Kaneko Muneaki Ishijima Xu Zhuang;Yasuhiro Homma;Taichi Sato;Tomonori Baba;Itaru Morohashi;Hideaki Iwase;Kazuo Kaneko;Muneaki Ishijima(Department of Orthopaedic Surgery, Juntendo University School of Medicine, Tokyo, Japan;Department of Advanced Machinery Engineering, Tokyo Denki University School of Engineering, Tokyo, Japan;Department of Orthopaedic Surgery, Juntendo University Shizuoka Hospital, Shizuoka, Japan;Department of Bio-Engineering, Shizuoka Medical Research Center for Disaster, Juntendo University Shizuoka Hos-pital, Shizuoka, Japan)

机构地区:[1]Department of Orthopaedic Surgery, Juntendo University School of Medicine, Tokyo, Japan [2]Department of Advanced Machinery Engineering, Tokyo Denki University School of Engineering, Tokyo, Japan [3]Department of Orthopaedic Surgery, Juntendo University Shizuoka Hospital, Shizuoka, Japan [4]Department of Bio-Engineering, Shizuoka Medical Research Center for Disaster, Juntendo University Shizuoka Hos-pital, Shizuoka, Japan

出  处:《Journal of Biomedical Science and Engineering》2022年第9期229-240,共12页生物医学工程(英文)

摘  要:Background: The aim of this study is to identify the factors influence on the broaching hammering sound character during cementless total hip arthroplasty. Methods: We analyzed frequency spectrum of the hammering sound for 49 cases of uncomplicated cementless THAs using two types of proximal-coated stem performed by experienced surgeons. Normalized sound pressure (NSP) of each 0.5 kHz frequency band in final stage of broach procedure was determined by the fast Fourier transform analysis. The relationships between those sound characteristics and femoral morphology such as canal calcar ratio (CCR), Canal flare index (CFI), morphological cortical index (MCI) and femoral shaft length (FSL) in different cementless stem were investigated. Results: In Accolade 2, CCR was positively related to NSP in several bands [Frequency band (kHz);r: 2.0 - 2.5;0.37, 4.5 - 5.0;0.37, 9.5 - 10.0;0.44], and negatively related to 7.5 - 8.0 kHz (r = -0.39). Negative correlations were observed among CFI and MCI in specific frequency bands (4.5 - 5.0, 5.0 - 5.5, and 7.5 - 8.0 kHz). In Taperloc Microplasty, strong correlations were found between FSL and the NSP of 7.5. - 8.0 kHz (r = 0.78) and CCR and the 7.5 - 8.0 kHz bands. There was significant difference of NSPs between high and low group divided by morphological parameters. Acoustic characteristics of NSPs between Accolade 2 and Microplasty were significantly different in 9 frequency bands. Conclusions: The hammering sound correlated with four parameters of the femoral morphology and differed in different types of proximal-coated stem. Those novel five factors are important to consider when to predict complications using acoustic analysis.Background: The aim of this study is to identify the factors influence on the broaching hammering sound character during cementless total hip arthroplasty. Methods: We analyzed frequency spectrum of the hammering sound for 49 cases of uncomplicated cementless THAs using two types of proximal-coated stem performed by experienced surgeons. Normalized sound pressure (NSP) of each 0.5 kHz frequency band in final stage of broach procedure was determined by the fast Fourier transform analysis. The relationships between those sound characteristics and femoral morphology such as canal calcar ratio (CCR), Canal flare index (CFI), morphological cortical index (MCI) and femoral shaft length (FSL) in different cementless stem were investigated. Results: In Accolade 2, CCR was positively related to NSP in several bands [Frequency band (kHz);r: 2.0 - 2.5;0.37, 4.5 - 5.0;0.37, 9.5 - 10.0;0.44], and negatively related to 7.5 - 8.0 kHz (r = -0.39). Negative correlations were observed among CFI and MCI in specific frequency bands (4.5 - 5.0, 5.0 - 5.5, and 7.5 - 8.0 kHz). In Taperloc Microplasty, strong correlations were found between FSL and the NSP of 7.5. - 8.0 kHz (r = 0.78) and CCR and the 7.5 - 8.0 kHz bands. There was significant difference of NSPs between high and low group divided by morphological parameters. Acoustic characteristics of NSPs between Accolade 2 and Microplasty were significantly different in 9 frequency bands. Conclusions: The hammering sound correlated with four parameters of the femoral morphology and differed in different types of proximal-coated stem. Those novel five factors are important to consider when to predict complications using acoustic analysis.

关 键 词:Total Hip Arthroplasty Cementless Stem Hammering Sound Fast Fourier Transform Femoral Morphology 

分 类 号:R62[医药卫生—整形外科]

 

参考文献:

正在载入数据...

 

二级参考文献:

正在载入数据...

 

耦合文献:

正在载入数据...

 

引证文献:

正在载入数据...

 

二级引证文献:

正在载入数据...

 

同被引文献:

正在载入数据...

 

相关期刊文献:

正在载入数据...

相关的主题
相关的作者对象
相关的机构对象