检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:Shehu Abdul Qadir Zailani Mohammed Bello Mashood Abiola Raji Junaidu Kabir Suleiman Maitala Yahuza Shehu Abdul Qadir Zailani;Mohammed Bello;Mashood Abiola Raji;Junaidu Kabir;Suleiman Maitala Yahuza(Department of Animal Health Technology, Bauchi State College of Agriculture, Bauchi State, Nigeria;Department of Veterinary Public Health and Preventive Medicine, Faculty of Veterinary Medicine, Ahmadu Bello University, Zaria, Nigeria;Department of Veterinary Microbiology, Faculty of Veterinary Medicine, University of Ilorin, Ilorin, Kwara State, Nigeria;Bacterial Zoonoses Laboratory, Department of Veterinary Public Health and Preventive Medicine, Faculty of Veterinary Medicine, Ahmadu Bello University, Zaria, Nigeria)
机构地区:[1]Department of Animal Health Technology, Bauchi State College of Agriculture, Bauchi State, Nigeria [2]Department of Veterinary Public Health and Preventive Medicine, Faculty of Veterinary Medicine, Ahmadu Bello University, Zaria, Nigeria [3]Department of Veterinary Microbiology, Faculty of Veterinary Medicine, University of Ilorin, Ilorin, Kwara State, Nigeria [4]Bacterial Zoonoses Laboratory, Department of Veterinary Public Health and Preventive Medicine, Faculty of Veterinary Medicine, Ahmadu Bello University, Zaria, Nigeria
出 处:《Open Journal of Medical Microbiology》2016年第1期3-8,共6页医学微生物学(英文)
摘 要:Microbial quality (MQ) of meat contact surfaces (MCS) of six major abattoirs was evaluated with a subsequent further isolation and identification of E. coli O157. Two hundred and forty 240 swab samples (SS) from MCS that include cutting equipment, floor, tables and transport media were collected for total aerobic plate count and isolation of E. coli O157. Results of the SS indicated a mean value 7.1 ± 0.3 log<sub>10</sub> cfu/cm<sup>2</sup>. A minimum value of 6.4 ± 0.6 log<sub>10</sub> cfu/cm<sup>2</sup> was recorded oncutting instrument from Ningi abattoir, while a maximum value of 7.8 ± 0.3 log<sub>10</sub> cfu/cm<sup>2</sup> was obtained from tables at Darazo abattoir. Only 3 (1.2%) of the 240 SS of the MCS were positive for E. coli O157 using the latex agglutination kit (Difco, Michigan, USA).Microbial quality (MQ) of meat contact surfaces (MCS) of six major abattoirs was evaluated with a subsequent further isolation and identification of E. coli O157. Two hundred and forty 240 swab samples (SS) from MCS that include cutting equipment, floor, tables and transport media were collected for total aerobic plate count and isolation of E. coli O157. Results of the SS indicated a mean value 7.1 ± 0.3 log<sub>10</sub> cfu/cm<sup>2</sup>. A minimum value of 6.4 ± 0.6 log<sub>10</sub> cfu/cm<sup>2</sup> was recorded oncutting instrument from Ningi abattoir, while a maximum value of 7.8 ± 0.3 log<sub>10</sub> cfu/cm<sup>2</sup> was obtained from tables at Darazo abattoir. Only 3 (1.2%) of the 240 SS of the MCS were positive for E. coli O157 using the latex agglutination kit (Difco, Michigan, USA).
关 键 词:ABATTOIRS E. coli O157 Meat Contact Surfaces Microbial Quality
分 类 号:TS2[轻工技术与工程—食品科学与工程]
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在链接到云南高校图书馆文献保障联盟下载...
云南高校图书馆联盟文献共享服务平台 版权所有©
您的IP:216.73.216.195