Evaluation of HIV Viral Load Activity at the Bacteriology-Virology Laboratory in the University Hospital Center of Brazzaville  

Evaluation of HIV Viral Load Activity at the Bacteriology-Virology Laboratory in the University Hospital Center of Brazzaville

在线阅读下载全文

作  者:Esther Nina Ontsira Ngoyi[1] Tanguy Mieret[1] Roland Bienvenu Ossibi Ibara[1] Axel Aloumba[1] Géril Obili Sekangue[1] Armel Claude Itoua[1] Irène Laure Opfou[1] Christian Diamant Mossoro-Kpinde[1] Hervé Léon Iloki[1] Bertrand Dupont[1] Christine Rouzioux[1] 

出  处:《Open Journal of Medical Microbiology》2019年第4期178-185,共8页医学微生物学(英文)

摘  要:Introduction: The bacteriology-virology laboratory of the teaching university hospital of Brazzaville, was equipped with a real-time PCR device like Miniopticon (Biorad? , France). The aim of this work was to do an evaluation of the HIV viral load activity, with a view to proposing some recommendations. Material and methods: Retrospective study, January 2013 to March 2015, in patients on first line ARV three-therapy, pre-inclusion therapy checkup in HIV positive patients, but again screening after sexual abuse in women or accident of exposure (AES). A blood sample on EDTA tube was made and RNA extraction with Qiagen kit. Ultrasensitive HIV-RNA quantification was performed using the Generic HIV real-time PCR assay (Biocentric?, Bandol, France). Results: 126 patients were included. The mean age was 37.63 years +/- 10.43 years, sex ratio F/H = 2.3. The HIV viral load was detectable in 94 cases (74.6%). Concerning patients with detectable viral load (copies/ml): 403 to 996 in 35 cases (37.23%), 1411 to 1812 in 41 cases (43.62%) and >1814 in 5 cases (5.32%) (therapeutic failure). Conclusion: This work reports success in the setting up of the molecular biology unit. Procedures that implement information and education actions on the risks associated with AES must be disclosed.Introduction: The bacteriology-virology laboratory of the teaching university hospital of Brazzaville, was equipped with a real-time PCR device like Miniopticon (Biorad? , France). The aim of this work was to do an evaluation of the HIV viral load activity, with a view to proposing some recommendations. Material and methods: Retrospective study, January 2013 to March 2015, in patients on first line ARV three-therapy, pre-inclusion therapy checkup in HIV positive patients, but again screening after sexual abuse in women or accident of exposure (AES). A blood sample on EDTA tube was made and RNA extraction with Qiagen kit. Ultrasensitive HIV-RNA quantification was performed using the Generic HIV real-time PCR assay (Biocentric?, Bandol, France). Results: 126 patients were included. The mean age was 37.63 years +/- 10.43 years, sex ratio F/H = 2.3. The HIV viral load was detectable in 94 cases (74.6%). Concerning patients with detectable viral load (copies/ml): 403 to 996 in 35 cases (37.23%), 1411 to 1812 in 41 cases (43.62%) and >1814 in 5 cases (5.32%) (therapeutic failure). Conclusion: This work reports success in the setting up of the molecular biology unit. Procedures that implement information and education actions on the risks associated with AES must be disclosed.

关 键 词:VIRAL Load HIV Miniopticon CHU BRAZZAVILLE 

分 类 号:R51[医药卫生—内科学]

 

参考文献:

正在载入数据...

 

二级参考文献:

正在载入数据...

 

耦合文献:

正在载入数据...

 

引证文献:

正在载入数据...

 

二级引证文献:

正在载入数据...

 

同被引文献:

正在载入数据...

 

相关期刊文献:

正在载入数据...

相关的主题
相关的作者对象
相关的机构对象