检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:Refat F. Aglan Gehad G. Mohamed Hala A. Mohamed
机构地区:[1]Chemistry Department, Faculty of Science, Cairo University, 12613 Giza, Egypt [2]Hot Laboratories Center, Atomic Energy Authority, 13759, Cairo, Egypt
出 处:《American Journal of Analytical Chemistry》2012年第8期576-586,共11页美国分析化学(英文)
摘 要:A new chemically modified carbon paste electrode for cesium(I) ion determination based on potassium zinc hexacyan-oferrate (PZHCF) as an ionophore was prepared. The electrode exhibits a Nernstian response for Cs(I) ions over a wide concentration range from 1 × 10-6 to 1 × 10-1 mol·L-1 with a slope of 58 ± 0.5 mV·decade-1. It has a response time of about 35 s and can be used for a period of 3 months with good reproducibility. Detection limit obtained in the optimal conditions was 3 × 10-7 mol·L-1. The potentiometric response is independent of the pH of the solution in the pH range 4.0 - 8.0. The electrode possesses the advantages of low resistance, fast response over a variety of other cations. The proposed electrode is applied as a sensor for the determination of Cs(I) ion concentration in different samples solutions. The results showed a good correlation with the data obtained by atomic absorption spectrometric method.A new chemically modified carbon paste electrode for cesium(I) ion determination based on potassium zinc hexacyan-oferrate (PZHCF) as an ionophore was prepared. The electrode exhibits a Nernstian response for Cs(I) ions over a wide concentration range from 1 × 10-6 to 1 × 10-1 mol·L-1 with a slope of 58 ± 0.5 mV·decade-1. It has a response time of about 35 s and can be used for a period of 3 months with good reproducibility. Detection limit obtained in the optimal conditions was 3 × 10-7 mol·L-1. The potentiometric response is independent of the pH of the solution in the pH range 4.0 - 8.0. The electrode possesses the advantages of low resistance, fast response over a variety of other cations. The proposed electrode is applied as a sensor for the determination of Cs(I) ion concentration in different samples solutions. The results showed a good correlation with the data obtained by atomic absorption spectrometric method.
关 键 词:CESIUM DETERMINATION Modified Ion Selective Electrode POTASSIUM ZINC HEXACYANOFERRATE IONOPHORE
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在链接到云南高校图书馆文献保障联盟下载...
云南高校图书馆联盟文献共享服务平台 版权所有©
您的IP:18.188.54.133