检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:Refat F. Aglan Mahmoud S. Rizk Gehad G. Mohamed Ahmed H. El-Wahy Hala A. Mohamed
机构地区:[1]Chemistry Administration, Cairo, Egypt [2]Chemistry Department, Faculty of Science, Cairo University, Giza, Egypt [3]Hot Laboratory Center, Atomic Energy Authority, Cairo, Egypt
出 处:《American Journal of Analytical Chemistry》2014年第2期140-148,共9页美国分析化学(英文)
摘 要:The new ferrous-selective modified carbon paste electrodes (I and II) based on 5,5’-(propane-1,3-diylbis(sulfanediyl))bis(3-benzyl-4H-1,2,4-triazol-4-amine) (electrode I, A-ionophore) and 5,5’-(butane-1,4-diyl-bis(sulfane- diyl))bis(3-benzyl-4H-1,2,4-triazol-4-amine) (electrode II, B-ionophore) as ionophores are described. These electrodes exhibit Nernstian slopes of 30.2 ± 0.5 and 29.1 ± 0.5 mV·decade-1, linear range of 1.0 × 10-7 - 1.0 × 10-2 mol·L-1 Fe(II) ion and detection limit of 1.0 × 10-7 mol·L-1 Fe(II) ion for electrode (I) and electrode (II), respectively. Both electrodes (I and II) have a fast response time of about 15 sand can be used for at least 3 months. The two electrodes revealed a good selectivity for Fe(II) over a wide variety of other metal ions and could be used in the pH range of 1.8 - 3.0 without any divergence in potential. The proposed sensors were successfully applied for the determination of Fe(II) ion in different real samples.The new ferrous-selective modified carbon paste electrodes (I and II) based on 5,5’-(propane-1,3-diylbis(sulfanediyl))bis(3-benzyl-4H-1,2,4-triazol-4-amine) (electrode I, A-ionophore) and 5,5’-(butane-1,4-diyl-bis(sulfane- diyl))bis(3-benzyl-4H-1,2,4-triazol-4-amine) (electrode II, B-ionophore) as ionophores are described. These electrodes exhibit Nernstian slopes of 30.2 ± 0.5 and 29.1 ± 0.5 mV·decade-1, linear range of 1.0 × 10-7 - 1.0 × 10-2 mol·L-1 Fe(II) ion and detection limit of 1.0 × 10-7 mol·L-1 Fe(II) ion for electrode (I) and electrode (II), respectively. Both electrodes (I and II) have a fast response time of about 15 sand can be used for at least 3 months. The two electrodes revealed a good selectivity for Fe(II) over a wide variety of other metal ions and could be used in the pH range of 1.8 - 3.0 without any divergence in potential. The proposed sensors were successfully applied for the determination of Fe(II) ion in different real samples.
关 键 词:Triazol IONOPHORES FERROUS Ion Determination Modified CARBON PASTE ELECTRODES
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在链接到云南高校图书馆文献保障联盟下载...
云南高校图书馆联盟文献共享服务平台 版权所有©
您的IP:18.116.239.69