检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:Sonia Di Berardino Renata Jasionowska
机构地区:[1]Department of Chemistry, Sapienza University, Rome, Italy
出 处:《American Journal of Analytical Chemistry》2014年第9期613-619,共7页美国分析化学(英文)
摘 要:A rapid and sensitive CZE (Capillary Zone Electrophoresis) method for pharmaceutical analysis was developed and fully validated. The active compounds: Pseudoephedrine hydrochloride (PSE), Triprolidine hydrochloride (TRI) and Paracetamol (PAR) were separated and quantitatively determined using the tris-borate 30 mM buffer at pH = 9.0 as a Background Electrolyte (BGE). The electrophoretic separation was carried out at 25 kV in an unmodified fused silica capillary of I.D. = 50 μm with a “bubble-cell” for UV detection at 210 nm and 25°C. The separation was reached in about 3 min. After calibration the method was applied for analysis of three commercially available pharmaceutical preparations. The repeatability (RSD%) of migration time (tm) was ranging between 0.47% and 0.90% and of peak areas (A) between 0.63% and 3.64%. The Limit of Detection (LOD) values was of 0.19 μg/mL, 0.31 μg/mL and 0.08 μg/mL for respectively PSE, TRI and PAR. The results obtained in this study showed that the proposed method was useful in routinely analysis of pharmaceuticals.A rapid and sensitive CZE (Capillary Zone Electrophoresis) method for pharmaceutical analysis was developed and fully validated. The active compounds: Pseudoephedrine hydrochloride (PSE), Triprolidine hydrochloride (TRI) and Paracetamol (PAR) were separated and quantitatively determined using the tris-borate 30 mM buffer at pH = 9.0 as a Background Electrolyte (BGE). The electrophoretic separation was carried out at 25 kV in an unmodified fused silica capillary of I.D. = 50 μm with a “bubble-cell” for UV detection at 210 nm and 25°C. The separation was reached in about 3 min. After calibration the method was applied for analysis of three commercially available pharmaceutical preparations. The repeatability (RSD%) of migration time (tm) was ranging between 0.47% and 0.90% and of peak areas (A) between 0.63% and 3.64%. The Limit of Detection (LOD) values was of 0.19 μg/mL, 0.31 μg/mL and 0.08 μg/mL for respectively PSE, TRI and PAR. The results obtained in this study showed that the proposed method was useful in routinely analysis of pharmaceuticals.
关 键 词:Capillary Zone ELECTROPHORESIS TRIPROLIDINE PSEUDOEPHEDRINE PARACETAMOL PHARMACEUTICAL Analysis Validation
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在链接到云南高校图书馆文献保障联盟下载...
云南高校图书馆联盟文献共享服务平台 版权所有©
您的IP:216.73.216.49