Rapid and Sensitive CZE Method for Quality Control Analysis of Pharmaceuticals Containing Pseudoephedrine, Triprolidine and Paracetamol  

Rapid and Sensitive CZE Method for Quality Control Analysis of Pharmaceuticals Containing Pseudoephedrine, Triprolidine and Paracetamol

在线阅读下载全文

作  者:Sonia Di Berardino Renata Jasionowska 

机构地区:[1]Department of Chemistry, Sapienza University, Rome, Italy

出  处:《American Journal of Analytical Chemistry》2014年第9期613-619,共7页美国分析化学(英文)

摘  要:A rapid and sensitive CZE (Capillary Zone Electrophoresis) method for pharmaceutical analysis was developed and fully validated. The active compounds: Pseudoephedrine hydrochloride (PSE), Triprolidine hydrochloride (TRI) and Paracetamol (PAR) were separated and quantitatively determined using the tris-borate 30 mM buffer at pH = 9.0 as a Background Electrolyte (BGE). The electrophoretic separation was carried out at 25 kV in an unmodified fused silica capillary of I.D. = 50 μm with a “bubble-cell” for UV detection at 210 nm and 25°C. The separation was reached in about 3 min. After calibration the method was applied for analysis of three commercially available pharmaceutical preparations. The repeatability (RSD%) of migration time (tm) was ranging between 0.47% and 0.90% and of peak areas (A) between 0.63% and 3.64%. The Limit of Detection (LOD) values was of 0.19 μg/mL, 0.31 μg/mL and 0.08 μg/mL for respectively PSE, TRI and PAR. The results obtained in this study showed that the proposed method was useful in routinely analysis of pharmaceuticals.A rapid and sensitive CZE (Capillary Zone Electrophoresis) method for pharmaceutical analysis was developed and fully validated. The active compounds: Pseudoephedrine hydrochloride (PSE), Triprolidine hydrochloride (TRI) and Paracetamol (PAR) were separated and quantitatively determined using the tris-borate 30 mM buffer at pH = 9.0 as a Background Electrolyte (BGE). The electrophoretic separation was carried out at 25 kV in an unmodified fused silica capillary of I.D. = 50 μm with a “bubble-cell” for UV detection at 210 nm and 25°C. The separation was reached in about 3 min. After calibration the method was applied for analysis of three commercially available pharmaceutical preparations. The repeatability (RSD%) of migration time (tm) was ranging between 0.47% and 0.90% and of peak areas (A) between 0.63% and 3.64%. The Limit of Detection (LOD) values was of 0.19 μg/mL, 0.31 μg/mL and 0.08 μg/mL for respectively PSE, TRI and PAR. The results obtained in this study showed that the proposed method was useful in routinely analysis of pharmaceuticals.

关 键 词:Capillary Zone ELECTROPHORESIS TRIPROLIDINE PSEUDOEPHEDRINE PARACETAMOL PHARMACEUTICAL Analysis Validation 

分 类 号:O6[理学—化学]

 

参考文献:

正在载入数据...

 

二级参考文献:

正在载入数据...

 

耦合文献:

正在载入数据...

 

引证文献:

正在载入数据...

 

二级引证文献:

正在载入数据...

 

同被引文献:

正在载入数据...

 

相关期刊文献:

正在载入数据...

相关的主题
相关的作者对象
相关的机构对象