检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:Minori Kamaya Hikaru Sugimoto Yosuke Yamaguchi
出 处:《American Journal of Analytical Chemistry》2014年第16期1121-1128,共8页美国分析化学(英文)
摘 要:A spectrophotometric approach for the detection of non-ionic surfactant (Triton X-100) has been proposed in this paper. This method does not involve extraction of the ion-associate with harmful solvents, but employs adhesion of the ion-association of potassium/non-ionic surfactants complex and tetraphenylporphyrin tetrasulfonic acid obtained by vigorous shaking. The adhered ion-associate was dissolved with water and its absorbance was measured. The sensitivity for Triton X-100 was determined to be 0.146 (expressed as absorbance of 1 mg/L solution). The adhesion tendency of ion-associate was found to be dependent on the water contact angle, which in turn was influenced by a high adhesion of the ion-associate and by low blank values. In this respect, a tetrafluo-roethylene vessel was found to be the most suitable for the detection of non-ionic surfactants. This spectrophotometrical method is simply and rapidly performed by a procedure based on mechanical shaking and can be employed to detect non-ionic surfactants containing more than 7 polyethylene oxide units.A spectrophotometric approach for the detection of non-ionic surfactant (Triton X-100) has been proposed in this paper. This method does not involve extraction of the ion-associate with harmful solvents, but employs adhesion of the ion-association of potassium/non-ionic surfactants complex and tetraphenylporphyrin tetrasulfonic acid obtained by vigorous shaking. The adhered ion-associate was dissolved with water and its absorbance was measured. The sensitivity for Triton X-100 was determined to be 0.146 (expressed as absorbance of 1 mg/L solution). The adhesion tendency of ion-associate was found to be dependent on the water contact angle, which in turn was influenced by a high adhesion of the ion-associate and by low blank values. In this respect, a tetrafluo-roethylene vessel was found to be the most suitable for the detection of non-ionic surfactants. This spectrophotometrical method is simply and rapidly performed by a procedure based on mechanical shaking and can be employed to detect non-ionic surfactants containing more than 7 polyethylene oxide units.
关 键 词:NON-IONIC SURFACTANT DETECTION SPECTROPHOTOMETRY TETRAPHENYLPORPHYRIN Tetrasulfonic Acid Ion-Associate Adhesion Potassium/Non-Ionic SURFACTANT Complex
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在链接到云南高校图书馆文献保障联盟下载...
云南高校图书馆联盟文献共享服务平台 版权所有©
您的IP:216.73.216.15