Green Photoluminescent Methodology for Aluminium Traces Quantification in 24-Hour Urine of Subjects with Different Exposition to Tobacco Smoke  

Green Photoluminescent Methodology for Aluminium Traces Quantification in 24-Hour Urine of Subjects with Different Exposition to Tobacco Smoke

在线阅读下载全文

作  者:Débora G. Santarossa María C. Talio Liliana P. Fernández 

机构地区:[1]Instituto de Química de San Luis (INQUISAL-CONICET), Chacabuco y Pedernera, San Luis, Argentina [2]área de Química Analítica, Facultad de Química, Bioquímica y Farmacia, Universidad Nacional de San Luis, San Luis, Argentina

出  处:《American Journal of Analytical Chemistry》2018年第10期514-528,共15页美国分析化学(英文)

摘  要:The aim of this work has been to evaluate the aluminium (Al(III)) traces contents in 24-hour urine samples from subjects with different tobacco smoke expositions using a new methodology with 1,4-dihydroxy-9, 10-anthraquinone (Quinizarine, QZ) as a fluorosphore. Biological samples were tested using commercial reagent strips and clinical parameters. Al(III) was determined complexing with QZ followed by a solid phase extraction step using Nylon membranes as a solid support. The analyte was subsequently quantified by solid surface fluorescence (SSF, λem= 573, λexc= 490) with a detection limit of 0.88 μg L-1 and quantification limit of 2.69 μg L-1. The calibration curve was linear from 2.69 to 499.13 μg L-1 Al(III) (R2 = 0.9973). Urine samples were successfully analysed with an average recovery close to 100%. Solid phase extraction step showed efficacy to eliminate foreign ions and the highly fluorescent matrix own of urine. Results were validated by electrothermal atomic absorption spectrometry (ETAAS) with an adequate concordance. The new methodology has low operation cost with simple instrumentation and without organic solvent.The aim of this work has been to evaluate the aluminium (Al(III)) traces contents in 24-hour urine samples from subjects with different tobacco smoke expositions using a new methodology with 1,4-dihydroxy-9, 10-anthraquinone (Quinizarine, QZ) as a fluorosphore. Biological samples were tested using commercial reagent strips and clinical parameters. Al(III) was determined complexing with QZ followed by a solid phase extraction step using Nylon membranes as a solid support. The analyte was subsequently quantified by solid surface fluorescence (SSF, λem= 573, λexc= 490) with a detection limit of 0.88 μg L-1 and quantification limit of 2.69 μg L-1. The calibration curve was linear from 2.69 to 499.13 μg L-1 Al(III) (R2 = 0.9973). Urine samples were successfully analysed with an average recovery close to 100%. Solid phase extraction step showed efficacy to eliminate foreign ions and the highly fluorescent matrix own of urine. Results were validated by electrothermal atomic absorption spectrometry (ETAAS) with an adequate concordance. The new methodology has low operation cost with simple instrumentation and without organic solvent.

关 键 词:Tobacco Aluminium TRACES 1 4-dihydroxy-9 10-anthraquinone (Quinizarine) SOLID Phase Extraction SOLID Surface Fluorescence URINE samples 

分 类 号:O6[理学—化学]

 

参考文献:

正在载入数据...

 

二级参考文献:

正在载入数据...

 

耦合文献:

正在载入数据...

 

引证文献:

正在载入数据...

 

二级引证文献:

正在载入数据...

 

同被引文献:

正在载入数据...

 

相关期刊文献:

正在载入数据...

相关的主题
相关的作者对象
相关的机构对象