检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:Adel B. Shehata Abdulrahman R. Al Askar Mohammed A. Al Rasheed Abdulrahman M. Al Zahrany Fahd A. Al Kharraa Sowailem A. Al Sowailem Adel B. Shehata;Abdulrahman R. Al Askar;Mohammed A. Al Rasheed;Abdulrahman M. Al Zahrany;Fahd A. Al Kharraa;Sowailem A. Al Sowailem(Chemistry Department/National Measurement and Calibration Center (NMCC), Saudi Standards, Metrology and Quality Organization (SASO), Riyadh, Kingdom of Saudi Arabia)
出 处:《Green and Sustainable Chemistry》2024年第2期17-28,共12页绿色与可持续化学(英文)
摘 要:The determination of the ethanol content in food products is of fundamental importance for HALAL certification. In this work, an analytical method for the determination of ethanol in water by headspace gas chromatography with flame ionization detector (HS-GC-FID) has been developed and validated for the use in characterization of ethanol reference materials. The validation study was carried out in the linear calibration range 100 - 1500 mg/kg using the NIST SRM 2900, nominal 95.6%. The studied performance characteristics of the method were the limit of detection, LOD, the limit of quantification LOQ, selectivity, linearity, precision, recovery and bias. The validation results showed that the method is selective, precise, accurate and free from any significant bias. The LOD and LOQ were 1.27 and 3.86 mg/kg respectively and the estimated expanded uncertainty was 2% indicating that the method is fit for the purpose of certification of ethanol in water reference materials.The determination of the ethanol content in food products is of fundamental importance for HALAL certification. In this work, an analytical method for the determination of ethanol in water by headspace gas chromatography with flame ionization detector (HS-GC-FID) has been developed and validated for the use in characterization of ethanol reference materials. The validation study was carried out in the linear calibration range 100 - 1500 mg/kg using the NIST SRM 2900, nominal 95.6%. The studied performance characteristics of the method were the limit of detection, LOD, the limit of quantification LOQ, selectivity, linearity, precision, recovery and bias. The validation results showed that the method is selective, precise, accurate and free from any significant bias. The LOD and LOQ were 1.27 and 3.86 mg/kg respectively and the estimated expanded uncertainty was 2% indicating that the method is fit for the purpose of certification of ethanol in water reference materials.
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在链接到云南高校图书馆文献保障联盟下载...
云南高校图书馆联盟文献共享服务平台 版权所有©
您的IP:3.145.165.235