Determination of Residual Chlorothalonil in Textiles  

Determination of Residual Chlorothalonil in Textiles

在线阅读下载全文

作  者:Chengyun Wang Junfeng Lin Tangtang Xie Huiping Zou Yalei Shen 

机构地区:[1]The Testing and Technology Center for Industrial Products, Shenzhen Customs, Shenzhen, China

出  处:《Journal of Materials Science and Chemical Engineering》2020年第4期106-114,共9页材料科学与化学工程(英文)

摘  要:An effective method was established to determine the content of residual chlorothalonil in textiles by gas chromatography/mass spectrometry-selected ion monitoring coupled with ultrasonic extraction technique. Residual chlorothalonil in textiles was ultrasonically extracted using ethyl acetate as the extraction solvent. The extract was condensed and analyzed by gas chromatography/mass spectrometry in selected ion monitoring mode (GC/MS-SIM). The concentration of chlorothalonil was calibrated by the external standard method. Good linearity existed between the peak area and the mass concentration of chlorothalonil in the mass concentration range from 0.2 μg/mL to 42.8 μg/mL. The equation was A = 95,399ρ ? 50,848, with a correlation coefficient of 0.9999. The limit of detection was 0.1 mg/kg for chlorothalonil. The blank samples were spiked at three concentration levels, and the spiked average recoveries changed from 81.9% to 95.4% while the relative standard deviation (RSD) changed from 1.8% to 5.2%. The proposed method was simple, rapid, sensitive and the limit of detection could meet the limit requirements of relevant regulations. Commercially available textiles were measured by this method, and chlorothalonil at different concentration levels was detected in some samples.An effective method was established to determine the content of residual chlorothalonil in textiles by gas chromatography/mass spectrometry-selected ion monitoring coupled with ultrasonic extraction technique. Residual chlorothalonil in textiles was ultrasonically extracted using ethyl acetate as the extraction solvent. The extract was condensed and analyzed by gas chromatography/mass spectrometry in selected ion monitoring mode (GC/MS-SIM). The concentration of chlorothalonil was calibrated by the external standard method. Good linearity existed between the peak area and the mass concentration of chlorothalonil in the mass concentration range from 0.2 μg/mL to 42.8 μg/mL. The equation was A = 95,399ρ ? 50,848, with a correlation coefficient of 0.9999. The limit of detection was 0.1 mg/kg for chlorothalonil. The blank samples were spiked at three concentration levels, and the spiked average recoveries changed from 81.9% to 95.4% while the relative standard deviation (RSD) changed from 1.8% to 5.2%. The proposed method was simple, rapid, sensitive and the limit of detection could meet the limit requirements of relevant regulations. Commercially available textiles were measured by this method, and chlorothalonil at different concentration levels was detected in some samples.

关 键 词:CHLOROTHALONIL TEXTILE ULTRASONIC EXTRACTION GC/MS-SIM 

分 类 号:F42[经济管理—产业经济]

 

参考文献:

正在载入数据...

 

二级参考文献:

正在载入数据...

 

耦合文献:

正在载入数据...

 

引证文献:

正在载入数据...

 

二级引证文献:

正在载入数据...

 

同被引文献:

正在载入数据...

 

相关期刊文献:

正在载入数据...

相关的主题
相关的作者对象
相关的机构对象