Uranium Series Disequilibrium and Precision Measurement of Radionuclides Activity in Sediment Sample Using Low Background Gamma Spectrometry  

Uranium Series Disequilibrium and Precision Measurement of Radionuclides Activity in Sediment Sample Using Low Background Gamma Spectrometry

在线阅读下载全文

作  者:Abdul J. Khan Umme-Farzana Syed Amy L. Roselan Cynthia A. Costello Abdul J. Khan;Umme-Farzana Syed;Amy L. Roselan;Cynthia A. Costello(Laboratory of Inorganic and Nuclear Chemistry, Division of Environmental Health Sciences, Wadsworth Center, New York State Department of Health, Empire State Plaza, Albany, NY, USA;Bureau of Environmental Radiation Protection, New York State Department of Health, Empire State Plaza, Albany, NY, USA)

机构地区:[1]Laboratory of Inorganic and Nuclear Chemistry, Division of Environmental Health Sciences, Wadsworth Center, New York State Department of Health, Empire State Plaza, Albany, NY, USA [2]Bureau of Environmental Radiation Protection, New York State Department of Health, Empire State Plaza, Albany, NY, USA

出  处:《Journal of Geoscience and Environment Protection》2023年第10期119-140,共22页地球科学和环境保护期刊(英文)

摘  要:Low background gamma spectrometry was used to measure the radionuclides activity of <sup>238</sup>U, <sup>232</sup>Th, and <sup>235</sup>U series as well as <sup>40</sup>K and <sup>137</sup>Cs in a sediment sample. The goal of the study was to measure the <sup>238</sup>U (63.3 keV peak of <sup>234</sup>Th;1001 keV peak of <sup>234m</sup>Pa) and <sup>235</sup>U (143.76 keV, 163.33 keV, and 205.31 keV peaks) activity by low background gamma spectrometry in sediment sample. <sup>235</sup>U activity in environmental samples is difficult to accurately measure by gamma spectrometry due to its low abundance in nature and low gamma line intensities at 143.76 keV, 163.33 keV, and 205.31 keV. We have shown that by using low background gamma spectrometry, it is possible to accurately measure the <sup>235</sup>U activity in sediment samples. The <sup>235</sup>U activity was measured without using the major peak of 185.7 keV (I<sub>γ</sub> = 57.2%) which requires interference correction from 186.21 keV of <sup>226</sup>Ra. <sup>226</sup>Ra activity was determined by measuring <sup>222</sup>Rn daughters (<sup>214</sup>Pb and <sup>214</sup>Bi). The precision and accuracy of the gamma activity measurement in the sediment sample were verified by using the HPGe detectors with Certified Reference Material (CRM) Irish Sea Sediment (IAEA-385). The results obtained for the 63.33 keV energy line of <sup>234</sup>Th are compared with the 1001 keV energy line of <sup>234m</sup>Pa. The values of <sup>238</sup>U and <sup>235</sup>U activities, as well as <sup>40</sup>K, <sup>137</sup>Cs, and <sup>226</sup>Ra, agreed with the certificate values of CRM. The results show that the <sup>238</sup>U is in equilibrium with its daughters (<sup>234</sup>Th, <sup>234m</sup>Pa, and <sup>210</sup>Pb). <sup>232</sup>Th is also in equilibrium with its daughters (<sup>228</sup>Ra, <sup>212</sup>Pb, <sup>212</sup>Bi and <sup>208</sup>Tl). <sup>235</sup>U/<sup>238</sup>U activity ratio of 0.046 ± 0.007 in the sediment is constant in nature but fluctuates Low background gamma spectrometry was used to measure the radionuclides activity of <sup>238</sup>U, <sup>232</sup>Th, and <sup>235</sup>U series as well as <sup>40</sup>K and <sup>137</sup>Cs in a sediment sample. The goal of the study was to measure the <sup>238</sup>U (63.3 keV peak of <sup>234</sup>Th;1001 keV peak of <sup>234m</sup>Pa) and <sup>235</sup>U (143.76 keV, 163.33 keV, and 205.31 keV peaks) activity by low background gamma spectrometry in sediment sample. <sup>235</sup>U activity in environmental samples is difficult to accurately measure by gamma spectrometry due to its low abundance in nature and low gamma line intensities at 143.76 keV, 163.33 keV, and 205.31 keV. We have shown that by using low background gamma spectrometry, it is possible to accurately measure the <sup>235</sup>U activity in sediment samples. The <sup>235</sup>U activity was measured without using the major peak of 185.7 keV (I<sub>γ</sub> = 57.2%) which requires interference correction from 186.21 keV of <sup>226</sup>Ra. <sup>226</sup>Ra activity was determined by measuring <sup>222</sup>Rn daughters (<sup>214</sup>Pb and <sup>214</sup>Bi). The precision and accuracy of the gamma activity measurement in the sediment sample were verified by using the HPGe detectors with Certified Reference Material (CRM) Irish Sea Sediment (IAEA-385). The results obtained for the 63.33 keV energy line of <sup>234</sup>Th are compared with the 1001 keV energy line of <sup>234m</sup>Pa. The values of <sup>238</sup>U and <sup>235</sup>U activities, as well as <sup>40</sup>K, <sup>137</sup>Cs, and <sup>226</sup>Ra, agreed with the certificate values of CRM. The results show that the <sup>238</sup>U is in equilibrium with its daughters (<sup>234</sup>Th, <sup>234m</sup>Pa, and <sup>210</sup>Pb). <sup>232</sup>Th is also in equilibrium with its daughters (<sup>228</sup>Ra, <sup>212</sup>Pb, <sup>212</sup>Bi and <sup>208</sup>Tl). <sup>235</sup>U/<sup>238</sup>U activity ratio of 0.046 ± 0.007 in the sediment is constant in nature but fluctuates

关 键 词:Low Background Gamma Spectrometry HPGe Detector SEDIMENT 238U 235U Secular Equilibrium 

分 类 号:O57[理学—粒子物理与原子核物理]

 

参考文献:

正在载入数据...

 

二级参考文献:

正在载入数据...

 

耦合文献:

正在载入数据...

 

引证文献:

正在载入数据...

 

二级引证文献:

正在载入数据...

 

同被引文献:

正在载入数据...

 

相关期刊文献:

正在载入数据...

相关的主题
相关的作者对象
相关的机构对象