Performances of a Bitumen Fume and Condensate Generation System for Sampling Method Development  被引量:1

Performances of a Bitumen Fume and Condensate Generation System for Sampling Method Development

在线阅读下载全文

作  者:Benjamin Sutter Eric Pelletier Christel Ravera Eddy Langlois Benjamin Sutter;Eric Pelletier;Christel Ravera;Eddy Langlois(Pollutants Metrology, Institut National de Recherche et Sécurité, Vandoeuvre-Les-Nancy, France)

机构地区:[1]Pollutants Metrology, Institut National de Recherche et Sécurité, Vandoeuvre-Les-Nancy, France

出  处:《Journal of Environmental Protection》2016年第7期973-984,共12页环境保护(英文)

摘  要:A laboratory system was designed to generate bitumen fumes and expose tested samplers in a homogenised chamber. The system was also designed to condense the fumes in the form of oil that could be used as a standard for further analytical method development. The laboratory system was evaluated in terms of stability, repeatability, aging, and ranges, focusing on the quality and quantity of the fumes and their physical characteristics. The fumes generated with the laboratory system were also compared to fumes emitted at workplaces to evaluate their similarity. The results demonstrated that laboratory fume generation was stable and repeatable. Humidity ranged from 20% to 80% RH and the total fume concentration ranged from 0.01 to 9.36 mg.m<sup>-3</sup>, covering the conditions encountered for road paving worksites. The fumes generated in the laboratory were found to be similar to those of workplaces, with slight differences in light compounds equivalent to C12 and below n-alkanes. Thus, the system designed in this study is considered capable of generating bitumen fumes used to develop sampling and analysis methods.A laboratory system was designed to generate bitumen fumes and expose tested samplers in a homogenised chamber. The system was also designed to condense the fumes in the form of oil that could be used as a standard for further analytical method development. The laboratory system was evaluated in terms of stability, repeatability, aging, and ranges, focusing on the quality and quantity of the fumes and their physical characteristics. The fumes generated with the laboratory system were also compared to fumes emitted at workplaces to evaluate their similarity. The results demonstrated that laboratory fume generation was stable and repeatable. Humidity ranged from 20% to 80% RH and the total fume concentration ranged from 0.01 to 9.36 mg.m<sup>-3</sup>, covering the conditions encountered for road paving worksites. The fumes generated in the laboratory were found to be similar to those of workplaces, with slight differences in light compounds equivalent to C12 and below n-alkanes. Thus, the system designed in this study is considered capable of generating bitumen fumes used to develop sampling and analysis methods.

关 键 词:BITUMEN FUMES Laboratory Generation Condensate Generation Road Paving 

分 类 号:TE6[石油与天然气工程—油气加工工程]

 

参考文献:

正在载入数据...

 

二级参考文献:

正在载入数据...

 

耦合文献:

正在载入数据...

 

引证文献:

正在载入数据...

 

二级引证文献:

正在载入数据...

 

同被引文献:

正在载入数据...

 

相关期刊文献:

正在载入数据...

相关的主题
相关的作者对象
相关的机构对象