Meta-Study of Particulate Detection Losses on Radioactive Air Sample Filters  

Meta-Study of Particulate Detection Losses on Radioactive Air Sample Filters

在线阅读下载全文

作  者:J. Matthew Barnett Hunter Z. Edwards J. Matthew Barnett;Hunter Z. Edwards(Pacific Northwest National Laboratory, Richland, USA)

机构地区:[1]Pacific Northwest National Laboratory, Richland, USA

出  处:《Journal of Environmental Protection》2022年第8期589-602,共14页环境保护(英文)

摘  要:Several mathematical relationships between air sample filter mass loading and the correlated analytical self-absorption factor were developed using data from other published research in this meta-study. Gross-alpha and -beta applications are addressed for this research. As filter media becomes loaded with particulate matter, there is potential for measurement losses due to self-absorption by mass loading. Components contributing to absorption include particulate dust, radioactive particulates, and filter material. Standards indicate a correction factor should be used when the penetration of radioactive material into the collection media or self-absorption of radiation by the material collected would reduce the detection rate by more than 5%. Previously, losses due to self-absorption have been reported up to 100% over a range up to ~10 mg⋅cm<sup>-2</sup> mass loading. These absorption losses then can be used to determine a correction factor for sample results. For low mass loadings (e.g., ≤0.1 mg⋅cm<sup>-2</sup>) corrections factors in the 0.85 - 1 range have been recommended and used, while at higher mass loadings nearer to 10 mg⋅cm<sup>-2</sup> correction factors closer to 0 (representing near 100% losses) are used. Based on data from published studies, the different methods for relating percent loss due to self-absorption to mass loading include linear, exponential, quadratic, and trinomial derived functions. Where applicable, both forced zero and non-forced zero results were evaluated. From the derived functions evaluated, the trinomial function provided the best fit. Once the sample filter mass loading is known, the trinomial function can be applied to estimate losses and the corresponding self-absorption factor. When applied to routine operating conditions for radiological facility stacks monitored at the Pacific Northwest National Laboratory for an average sample filter mass loading of 0.09 ± 0.12 (2σ) mg⋅cm<sup>-2</sup> (excluding negative values and outliers) and a range from 0 - 0.24 mg⋅cm<Several mathematical relationships between air sample filter mass loading and the correlated analytical self-absorption factor were developed using data from other published research in this meta-study. Gross-alpha and -beta applications are addressed for this research. As filter media becomes loaded with particulate matter, there is potential for measurement losses due to self-absorption by mass loading. Components contributing to absorption include particulate dust, radioactive particulates, and filter material. Standards indicate a correction factor should be used when the penetration of radioactive material into the collection media or self-absorption of radiation by the material collected would reduce the detection rate by more than 5%. Previously, losses due to self-absorption have been reported up to 100% over a range up to ~10 mg⋅cm<sup>-2</sup> mass loading. These absorption losses then can be used to determine a correction factor for sample results. For low mass loadings (e.g., ≤0.1 mg⋅cm<sup>-2</sup>) corrections factors in the 0.85 - 1 range have been recommended and used, while at higher mass loadings nearer to 10 mg⋅cm<sup>-2</sup> correction factors closer to 0 (representing near 100% losses) are used. Based on data from published studies, the different methods for relating percent loss due to self-absorption to mass loading include linear, exponential, quadratic, and trinomial derived functions. Where applicable, both forced zero and non-forced zero results were evaluated. From the derived functions evaluated, the trinomial function provided the best fit. Once the sample filter mass loading is known, the trinomial function can be applied to estimate losses and the corresponding self-absorption factor. When applied to routine operating conditions for radiological facility stacks monitored at the Pacific Northwest National Laboratory for an average sample filter mass loading of 0.09 ± 0.12 (2σ) mg⋅cm<sup>-2</sup> (excluding negative values and outliers) and a range from 0 - 0.24 mg⋅cm<

关 键 词:Air Sampling Environmental Radioactivity SELF-ABSORPTION Correction Factor Standards 

分 类 号:O57[理学—粒子物理与原子核物理]

 

参考文献:

正在载入数据...

 

二级参考文献:

正在载入数据...

 

耦合文献:

正在载入数据...

 

引证文献:

正在载入数据...

 

二级引证文献:

正在载入数据...

 

同被引文献:

正在载入数据...

 

相关期刊文献:

正在载入数据...

相关的主题
相关的作者对象
相关的机构对象