Public Effective Dose Assessment Using Gross Alpha and Beta Radioactivity Levels of Tap Drinking Water in the District of Abidjan, Cote d’Ivoire  

Public Effective Dose Assessment Using Gross Alpha and Beta Radioactivity Levels of Tap Drinking Water in the District of Abidjan, Cote d’Ivoire

在线阅读下载全文

作  者:Ponaho Claude Kezo Issa Konate Tekpo Paul Dali Ponaho Claude Kezo;Issa Konate;Tekpo Paul Dali(Laboratory of Environmental Science and Technology, Université Jean Lorougnon Guédé, Daloa, Côte d’Ivoire;Laboratory of Environmental and Solar Energy Sciences, Université Félix Houphouët-Boigny, Abidjan, Côte d’Ivoire)

机构地区:[1]Laboratory of Environmental Science and Technology, Université Jean Lorougnon Guédé, Daloa, Côte d’Ivoire [2]Laboratory of Environmental and Solar Energy Sciences, Université Félix Houphouët-Boigny, Abidjan, Côte d’Ivoire

出  处:《Journal of Environmental Protection》2023年第3期127-138,共12页环境保护(英文)

摘  要:In order to assess public effective dose due to gross alpha and beta in water, 43 tap water samples were collected from different areas in the District of Abidjan. Using the low background Gas-less Automatic Alpha/Beta counting system (Canberra iMatic<sup>TM</sup>) for analysis, the gross alpha and beta concentrations found varied from 0.001 ± 0.002 to 0.063 ± 0.050 Bq/l with an average of 0.013 ± 0.012 Bq/l and from 0.067 ± 0.080 to 0.320 ± 0.120 Bq/l with an average of 0.174 ± 0.076 Bq/l, respectively in samples. The public effective dose assessment showed values of dose to ingestion of alpha and beta emitter radionuclides lower than the recommended value of dose for drinking water 0.1 mSv/y, except in 30% of the samples. These results show the need for additional studies to be conducted in order to clarify the hazardousness of these water samples. However, this study still remains important because it has provided necessary data for future tap water quality monitoring studies in the District of Abidjan.In order to assess public effective dose due to gross alpha and beta in water, 43 tap water samples were collected from different areas in the District of Abidjan. Using the low background Gas-less Automatic Alpha/Beta counting system (Canberra iMatic<sup>TM</sup>) for analysis, the gross alpha and beta concentrations found varied from 0.001 ± 0.002 to 0.063 ± 0.050 Bq/l with an average of 0.013 ± 0.012 Bq/l and from 0.067 ± 0.080 to 0.320 ± 0.120 Bq/l with an average of 0.174 ± 0.076 Bq/l, respectively in samples. The public effective dose assessment showed values of dose to ingestion of alpha and beta emitter radionuclides lower than the recommended value of dose for drinking water 0.1 mSv/y, except in 30% of the samples. These results show the need for additional studies to be conducted in order to clarify the hazardousness of these water samples. However, this study still remains important because it has provided necessary data for future tap water quality monitoring studies in the District of Abidjan.

关 键 词:Gross Alpha and Beta Concentration Tap Water Effective Dose District of Abidjan 

分 类 号:TP3[自动化与计算机技术—计算机科学与技术]

 

参考文献:

正在载入数据...

 

二级参考文献:

正在载入数据...

 

耦合文献:

正在载入数据...

 

引证文献:

正在载入数据...

 

二级引证文献:

正在载入数据...

 

同被引文献:

正在载入数据...

 

相关期刊文献:

正在载入数据...

相关的主题
相关的作者对象
相关的机构对象