Performance Characteristics of Pollutants along the Longitudinal Profile of a Subsurface Flow Constructed Wetland Domestic Sewage Treatment Plant in the University of Lagos, Nigeria  被引量:1

Performance Characteristics of Pollutants along the Longitudinal Profile of a Subsurface Flow Constructed Wetland Domestic Sewage Treatment Plant in the University of Lagos, Nigeria

在线阅读下载全文

作  者:Adelere Ezekiel Adeniran Adetinuke Aina Omolaraeni Oshunrinade 

机构地区:[1]Department of Civil & Environmental Engineering and Director of Works & Physical Planning, University of Lagos, Lagos, Nigeria [2]Works and Physical Planning Department, University of Lagos, Lagos, Nigeria

出  处:《Journal of Water Resource and Protection》2014年第2期104-113,共10页水资源与保护(英文)

摘  要:The paper reports the findings of a research work carried out to examine the performance and efficiency of a subsurface constructed wetland (SSFCW) for the treatment of domestic sewage in the University of Lagos (Unilag), Nigeria. The removal patterns and efficiencies of the physical, chemical and biological sewage pollutants parameters of domestic waste water generated within Unilag community by the SSFCW were studied. The wastewater was sampled and analysed along the SSFCW from influent (point1) to effluent (point 11). Total Dissolved Solids (TDS) reduced from 471 mg/l to 11.85 mg/l (97.48%), Turbidity reduced from 108.75 HTU to 0.05HTU (99.95%), Manganese reduced from 6.05 mg/l to 0.61 mg/ (89.92%), Nitrate reduced from 27.5 mg/l to 2.0 mg/l (92.73%), Sulphate reduced from 48.5 mg/l to 28 mg/l (42.27%), Iron reduced from 1.13 mg/l to 0.03 mg/l (97.35%), BOD reduced from 73.14 mg/l to 12.8 mg/l (82.5%), and E-coli reduced from 874 MPN/100 ml to 0.15 MPN/100 ml (99.98%). On the other hand, Dissolved Oxygen content increased along the SSFCW from 3.14 mg/l to 7.49 mg/l (138.54%) while the pH improved from slightly acid level of 6.49 to slightly above neutral level of 7.05 (9.3%). All the parameters at effluent point are within the Nigerian Federal Environmental Protection Agency (FEPA) acceptable standard. The study concludes that the SSFCW is a cheap, efficient and appropriate technology for the treatment of domestic sewage under tropical conditions.The paper reports the findings of a research work carried out to examine the performance and efficiency of a subsurface constructed wetland (SSFCW) for the treatment of domestic sewage in the University of Lagos (Unilag), Nigeria. The removal patterns and efficiencies of the physical, chemical and biological sewage pollutants parameters of domestic waste water generated within Unilag community by the SSFCW were studied. The wastewater was sampled and analysed along the SSFCW from influent (point1) to effluent (point 11). Total Dissolved Solids (TDS) reduced from 471 mg/l to 11.85 mg/l (97.48%), Turbidity reduced from 108.75 HTU to 0.05HTU (99.95%), Manganese reduced from 6.05 mg/l to 0.61 mg/ (89.92%), Nitrate reduced from 27.5 mg/l to 2.0 mg/l (92.73%), Sulphate reduced from 48.5 mg/l to 28 mg/l (42.27%), Iron reduced from 1.13 mg/l to 0.03 mg/l (97.35%), BOD reduced from 73.14 mg/l to 12.8 mg/l (82.5%), and E-coli reduced from 874 MPN/100 ml to 0.15 MPN/100 ml (99.98%). On the other hand, Dissolved Oxygen content increased along the SSFCW from 3.14 mg/l to 7.49 mg/l (138.54%) while the pH improved from slightly acid level of 6.49 to slightly above neutral level of 7.05 (9.3%). All the parameters at effluent point are within the Nigerian Federal Environmental Protection Agency (FEPA) acceptable standard. The study concludes that the SSFCW is a cheap, efficient and appropriate technology for the treatment of domestic sewage under tropical conditions.

关 键 词:Subsurface Flow Constructed WETLAND DOMESTIC SEWAGE POLLUTANTS Removal 

分 类 号:X7[环境科学与工程—环境工程]

 

参考文献:

正在载入数据...

 

二级参考文献:

正在载入数据...

 

耦合文献:

正在载入数据...

 

引证文献:

正在载入数据...

 

二级引证文献:

正在载入数据...

 

同被引文献:

正在载入数据...

 

相关期刊文献:

正在载入数据...

相关的主题
相关的作者对象
相关的机构对象