Study on the Plugging System of the Lower Ancient High Loss Zone in Changqing Gas Field  

Study on the Plugging System of the Lower Ancient High Loss Zone in Changqing Gas Field

在线阅读下载全文

作  者:Yan Gao Zuwen Wang Xiuli Shao Dichen Tan Erping Liu Yan Gao;Zuwen Wang;Xiuli Shao;Dichen Tan;Erping Liu(Chuanqing Drilling Engineering Company Underground Operation Company, Xi’an, China;Yangtze University, Jingzhou, China;Liaohe Oil Safety and Environment Protection Technical Supervision Center, Panjin, China)

机构地区:[1]Chuanqing Drilling Engineering Company Underground Operation Company, Xi’an, China [2]Yangtze University, Jingzhou, China [3]Liaohe Oil Safety and Environment Protection Technical Supervision Center, Panjin, China

出  处:《Open Journal of Yangtze Oil and Gas》2021年第1期1-12,共12页长江油气(英文版)

摘  要:At present, in the workover operations of old gas wells in the Changqing Gas Field, due to years of exploitation in the production layer, pressure deficits, and general leakage during the well killing, the well must be plugged before the well can be killed. In particular, the fracture-cavity type fractures of the lower paleocarbonate reservoirs have serious leakage. Traditional plugging materials and traditional plugging materials and methods have some limitations in dealing with leakage problems. Therefore, a composite plugging system using polymer solution as the base carrier fluid, multi-particle size rigid particles, expandable particles and modified fibers is developed. Its formula is: water + 2% polyacrylamide + 0.1% N, N-methylene bisacrylamide polymer gel is the base carrier fluid;the formulation of the particle plugging agent was continuously optimized through the CDL-II high temperature and high pressure dynamic and static plugging ability to plug the core. The final formulation of the plugging agent is: 1) 20% rigid particles (5 mm, 1 mm, 0.5 mm CCP-3 ratio 4:2:1) + 1% 3 mm expanded particles SMK-1 + 1% 1 ~ 2 mm fiber SRXW-10;2) 20% rigid particles (3 mm, 0.1 mm, 0.05 mm CCP-3 ratio 3:2:1) + 1% 3 mm expanded particles SMK-1 + 1% 1 ~ 2 mm fiber SRXW-10. The water swelling multiples of the granular plugging agent in salt water are all above 7 times, which meets the requirements of leak-proof plugging operations under high salinity;3% HCl is selected as the gel breaker, and the plugging system has a gel breaking rate of 95%;through the water plugging and profile control experimental system, the sand-filled pipe is used to simulate the plugging effect under high temperature and high pressure, and the plugging system can be sealed for 5 days at a high temperature of 110°C and a high pressure of 20 MPa to achieve a good plugging of the formation. It is expected that the developed plugging system has a good application prospect in future workover operations.At present, in the workover operations of old gas wells in the Changqing Gas Field, due to years of exploitation in the production layer, pressure deficits, and general leakage during the well killing, the well must be plugged before the well can be killed. In particular, the fracture-cavity type fractures of the lower paleocarbonate reservoirs have serious leakage. Traditional plugging materials and traditional plugging materials and methods have some limitations in dealing with leakage problems. Therefore, a composite plugging system using polymer solution as the base carrier fluid, multi-particle size rigid particles, expandable particles and modified fibers is developed. Its formula is: water + 2% polyacrylamide + 0.1% N, N-methylene bisacrylamide polymer gel is the base carrier fluid;the formulation of the particle plugging agent was continuously optimized through the CDL-II high temperature and high pressure dynamic and static plugging ability to plug the core. The final formulation of the plugging agent is: 1) 20% rigid particles (5 mm, 1 mm, 0.5 mm CCP-3 ratio 4:2:1) + 1% 3 mm expanded particles SMK-1 + 1% 1 ~ 2 mm fiber SRXW-10;2) 20% rigid particles (3 mm, 0.1 mm, 0.05 mm CCP-3 ratio 3:2:1) + 1% 3 mm expanded particles SMK-1 + 1% 1 ~ 2 mm fiber SRXW-10. The water swelling multiples of the granular plugging agent in salt water are all above 7 times, which meets the requirements of leak-proof plugging operations under high salinity;3% HCl is selected as the gel breaker, and the plugging system has a gel breaking rate of 95%;through the water plugging and profile control experimental system, the sand-filled pipe is used to simulate the plugging effect under high temperature and high pressure, and the plugging system can be sealed for 5 days at a high temperature of 110°C and a high pressure of 20 MPa to achieve a good plugging of the formation. It is expected that the developed plugging system has a good application prospect in future workover operations.

关 键 词:Lower Ancient High Loss Layer Plugging Gel Particle Plugging Agent Gel Breaking Performance Plugging Performance 

分 类 号:P64[天文地球—地质矿产勘探]

 