MAGNETOMETER

作品数:136被引量:185H指数:7
导出分析报告
相关领域:理学更多>>
相关作者:张军王直武凌祺更多>>
相关机构:清华大学江苏科技大学更多>>
相关期刊:更多>>
相关基金:国家自然科学基金国家重点基础研究发展计划中国博士后科学基金北京市自然科学基金更多>>
-

检索结果分析

结果分析中...
选择条件:
  • 期刊=Chinese Physics Lettersx
条 记 录,以下是1-10
视图:
排序:
An Atomic Magnetometer with Spin-Projection Noise Proportional to (T_2)^(1/2)
《Chinese Physics Letters》2019年第2期4-7,共4页Hai-Feng Dong Xiao-Fei Wang Ji-Min Li Jing-Ling Chen Yuan Ren 
Supported by the National Natural Science Foundation of China under Grant Nos 51675034 and 61273067;the Natural Science Foundation of Beijing Municipality under Grant No 7172123
There is a comm on sense view for atomic magnetometers that their spin-projection-noises(SPNs) are inversely proportional to (T_2)^(1/2), where (T_2)^(1/2) is the transverse relaxation time. We analyze the current ato...
关键词:AN ATOMIC MAGNETOMETER with Spin-Projection Noise Proportional to T2 
All-Optical Vector Cesium Magnetometer被引量:3
《Chinese Physics Letters》2017年第5期124-127,共4页孙伟民 黄强 黄宗军 王平稳 张军海 
Supported by the National Natural Science Foundation of China under Grant Nos U1631239 and U1331114;the 111 Project to Harbin Engineering University under Grant No B13015
Based on power modulation of a pump laser and precessional projection detection, we present an all-optical vector magnetometer of cesium, which has a demonstrated magnitude sensitivity of 80fF/Hz^1/2 and an orientatio...
关键词:All-Optical Vector Cesium Magnetometer 
Close-Loop Bell-Bloom Magnetometer with Amplitude Modulation被引量:1
《Chinese Physics Letters》2015年第9期174-177,共4页黄海超 董海峰 郝慧杰 胡旭阳 
Supported by the National Natural Science Foundation of China under Grant Nos 61273067 and 61074171;the National Basic Research Program of China under Grant No 2012CB934104
A high sensitive optical amplitude modulation magnetometer is investigated and demonstrated experimentally. We build an experimental platform for the atomic magnetometer and configure it as a Bell-Bloom magnetometer w...
关键词:Close-Loop Bell-Bloom Magnetometer with Amplitude Modulation 
Domain Structure and Magnetization Process in Short Glass-Coated Amorphous Microwires with Positive Magnetostriction
《Chinese Physics Letters》2012年第10期209-212,共4页LIU Kai-Huang LU Zhi-Chao LI De-Ren LIU Tian-Cheng ZHOU Shao-Xiong 
Supported by the National Natural Science Foundation of China under Grant No 50771034.
The domain structure and magnetisation process in short glass-coated amorphous Fe45Co20Ni10Si9B16 microwires are investigated by analyzing the hysteresis loops measured by a vibrating sample magnetometer.Methods of ca...
关键词:CRITICAL outer MAGNETOMETER 
A High Sensitivity Laser-Pumped Cesium Magnetometer
《Chinese Physics Letters》2012年第10期18-20,共3页HUANG Kai-Kai LI Nan LU Xuan-Hui 
Supported in part by the National Basic Research Program of China under Grant No 2012CB921602;the National Natural Science Foundation of China under Grant Nos 10874012,10974177;the Program of International Science and Technology Cooperation of China under Grant No 2010DFA04690。
An atomic magnetometer based on optically detected magnetic resonance is investigated and demonstrated experimentally.We build an 894 nm external cavity diode laser which is frequency locked to the F=4→F'=3 transitio...
关键词:MAGNETOMETER CAVITY COHERENT 
FMAA-MS Investigation into Ni_(68)Fe_(32) Nanoalloy with Sample Length Less than 30mm
《Chinese Physics Letters》2011年第8期221-224,共4页LI Ping-Yun CAO Zhen-Hua JIANG Zhong-Hao MENG Xiang-Kang 
by the National Basic Research Program of China under Grant No 2010CB631004;the Fundamental Research Funds for the Central Universities(1112021302,1106021343 and 1116021301);the PAPD,and the National Natural Science Foundation of China(11004098,50831004,51001060).
An investigation into the properties of nanocrystalline(NC)materials with sample lengths less than 30 mm seems to be a challenge by using conventional mechanical spectroscopy(MS).We use a newly developed frequency mod...
关键词:alloy FRICTION MAGNETOMETER 
CPT Magnetometer with Atomic Energy Level Modulation被引量:4
《Chinese Physics Letters》2008年第2期472-474,共3页刘国宾 杜润昌 刘朝阳 顾思洪 
Supported by National Natural Science Foundation of China under Grant Nos 10574141 and 10675162.
We propose and experimentally investigate a coherent population trapping state based magnetometer prototype with ^87Rb atoms. Through modulating Zeeman sublevels with an ac magnetic field, not only a phase sensitive d...
关键词:PHASE COHERENCE CLOCKS 
A Volt-Second Source for Calibration of Integrator in a Pulsed Field Magnetometer被引量:3
《Chinese Physics Letters》2007年第11期3088-3091,共4页林安利 贺建 张跃 John Dudding Michael Hall 
A volt-second (Vs) source intended for absolutely calibrating the integrator in a pulsed field magnetometer (PFM) is designed and proven to be with accurate rising and falling edges and reasonable lower uncertaint...
Tl_(2)Ba_(2)CaCu_(2)O_(x) Bicrystal Junction DC-SQUID Magnetometers Operating in Unshielded Environment被引量:1
《Chinese Physics Letters》2000年第11期847-849,共3页HAN Bing CHEN Geng-Hua ZHANG Li-Hua ZHAO Shi-Ping YANG Qian-Sheng YAN Shao-Lin LU Rong-Tao 
Supported by the National Center for R&D on Superconductivity and the Ministry of Science and Technology of China(NKBRSF-G19990646).
We fabricated direct-current superconducting quantum interference device magnetometers with single layer epi-taxial Tl_(2)Ba_(2)CaCu_(2)O_(x) films on 36.8° SrTiO_(3) bicrystal substrates.The white Aux noise and the ...
关键词:MAGNETOMETER CRYSTAL SQUID 
Field and Current Distribution in Superconducting Film Under Partial Field Penetration
《Chinese Physics Letters》1997年第9期701-704,共4页XU Xiao-nong SUN Ai-min DING Shi-ying JIN Xin YAO Xi-xian YAN Shao-lin WEN Hai-hu 
Supported by the National Foundation for Doctoral Education;the National Center for Research and Development on Superconductivity.
Using finite-element analysis in a self-consistent way with the self-field of the current considered for superconducting thin film,the field and current distributions under partial field penetration are calculated bas...
关键词:FIELD MAGNETOMETER vibrating 
检索报告 对象比较 聚类工具 使用帮助 返回顶部