大型有源相控阵校准的MCM法及其误差分析  被引量:20

MCM of Large Active Phased Array Calibrationand Tolerance Analysis

在线阅读下载全文

作  者:高 铁[1] 王金元[1] 

机构地区:[1]南京电子技术研究所,南京210013

出  处:《微波学报》2002年第1期6-10,19,共6页Journal of Microwaves

摘  要:文献[1,2]对相控阵天线校准采用互耦测量的方法进行了讨论。本文对此方法进行了推广、并提出了一种用互耦法进行大型有源相控阵校准的新方法──MCM法[3,4]。在整个监测校准过程中,校准测量与各有源通道收/发监测信号幅相大小无关。本文进一步对MCM法的测量误差进行了研究,同时给出了MCM法和近场实测结果,并进行了比较。理论分析和实验结果表明,该方法在工程应用中具有较大的实用价值。Abstract: Phased array antenna calibration using mutual coupling measurements is discussed in [1, 2]. A newway of large active phased array calibration with Mutual Coupling Method (MCM) is presented which the wholecalibration process is independent on the amplitude and phase of the transmittng/receiving signals in each activepath[3,4]. The statistics of the results on MCM are discussed, some experimental results measured by MCM andNear-Field are given and compared in this paper. Theoretical analysis and measurement results show that MCM hassignificant practical value in engineering applications.

关 键 词:有源相控阵 校准 互耦 低副瓣天线 误差分析 

分 类 号:TN82[电子电信—信息与通信工程]

 