检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
机构地区:[1]Department of Chemistry, Sciences College of Xi'an Jiaotong University, Xi'an 710061, China
出 处:《Journal of Pharmaceutical Analysis》2006年第2期136-138,共3页药物分析学报(英文版)
摘 要:Objective To establish a rapid and precise continuous flow-injection chemiluminescence method for the determination of tetracycline and oxytetracycline. Methods In NaOH solution, tetracycline and oxytetracycline can sensitize obviously the chemiluminesence (CL) intensity of the reaction of luminol with KIO_4, the sensitized CL intensity is proportional to the concentration of tetracycline and oxytetracycline. So, a new flow-injection CL method has been developed. The optimum chemical conditions for the CL reaction were investigated. Results Under the optimized conditions (KIO_ 4 concentration: 1.0×10 -5 mol/L; NaOH concentration: 0.1 mol/L; luminol concentration: 1.0×10 -4mol/L), tetracycline and oxytetracycline were determined. The linear range of the working curves was 1.0×10 -7 - 1.0×10 -4g/mL, the detection limits was 1.0×10 -8g/mL and 1.1×10 -8g/mL, and the relative standard deviation was 2.6% (C_S=1.0×10 -6g/mL; n=11) and 2.0% (C_S=1.0×10 -6g/mL; n=11) respectively. Conclusion The method is simple, rapid, and sensitive, and it has been successfully applied to the the determination of tetracycline and oxytetracycline tablets, the mean recoveries being 99.7% and 98.8% respectively.Objective To establish a rapid and precise continuous flow-injection chemiluminescence method for the determination of tetracycline and oxytetracycline. Methods In NaOH solution, tetracycline and oxytetracycline can sensitize obviously the chemiluminesence (CL) intensity of the reaction of luminol with KIO_4, the sensitized CL intensity is proportional to the concentration of tetracycline and oxytetracycline. So, a new flow-injection CL method has been developed. The optimum chemical conditions for the CL reaction were investigated. Results Under the optimized conditions (KIO_ 4 concentration: 1.0×10 -5 mol/L; NaOH concentration: 0.1 mol/L; luminol concentration: 1.0×10 -4mol/L), tetracycline and oxytetracycline were determined. The linear range of the working curves was 1.0×10 -7 - 1.0×10 -4g/mL, the detection limits was 1.0×10 -8g/mL and 1.1×10 -8g/mL, and the relative standard deviation was 2.6% (C_S=1.0×10 -6g/mL; n=11) and 2.0% (C_S=1.0×10 -6g/mL; n=11) respectively. Conclusion The method is simple, rapid, and sensitive, and it has been successfully applied to the the determination of tetracycline and oxytetracycline tablets, the mean recoveries being 99.7% and 98.8% respectively.
关 键 词:FLOW-INJECTION CHEMILUMINESCENCE TETRACYCLINE OXYTETRACYCLINE
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在链接到云南高校图书馆文献保障联盟下载...
云南高校图书馆联盟文献共享服务平台 版权所有©
您的IP:216.73.216.158