The correlation between rat retinal nerve fiber layer thickness around optic disc by using optical coherence tomography and histological measurements  被引量:2

The correlation between rat retinal nerve fiber layer thickness around optic disc by using optical coherence tomography and histological measurements

在线阅读下载全文

作  者:Ju-Fang Huang Hui-Min Yu Lei Shang Ruo-Fei Ma Ngobe Akume Cynthia Yan-Qun Cao Jia Luo Le-Ping Zeng Dan Chen Kun Xiong 

机构地区:[1]Department of Anatomy and Neurobiology,Central South University School of Basic Medical Sciences [2]Department of Ophthalmology,Central South University Third Xiangya Hospital [3]Central South University Xiangya School of Medicine [4]Department of Anatomy,Shaoyang Medical College

出  处:《International Journal of Ophthalmology(English edition)》2013年第4期415-421,共7页国际眼科杂志(英文版)

基  金:National Natural Science Foundation of China (No.81070729,No.81100663);Doctoral Foundation of Ministry of Education of China (No.20100162110067);Natural Science Foundation of Hunan Province (No.11JJ2020);Young Teachers Training Program of University of Hunan Province

摘  要:·AIM: To explore the correlation between the retinal nerve fiber layer (RNFL) thickness by using optical coherence tomography (OCT) and by histological measurements in normal adult rats and optic nerve transected rats. · METHODS: The RNFL thickness of 36 rats was scanned in a circle 3.46mm far from the optic disc by OCT. The two experimental groups were the normal group ( =20 rats) and the optic nerve transected group ( =16 rats). The latter group included 4 groups ( =4 /group) surviving for 1 day, 3, 5 and 7 days. Then the RNFL thickness of the same retina area was also measured by NF -200 immunohistochemical staining method. Linear regression was used to analyze the correlation between the data obtained from these two methods. ·RESULTS: The RNFL thickness of normal right eyes around optic disc by OCT was 72.35 ±5.71μm and that of the left eyes was 72.65 ±5.88μm ( =0.074). The RNFL thickness of the corresponding histological section by immunohistochemistry was 37.54 ±4.05μm (right eyes) and 37.38 ±4.23μm (left eyes) ( =0.059). There was a good correlation between the RNFL thickness measured by OCT and that measured by histology (R 2 =0.8131). After optic nerve transection, the trend of the RNFL thickness was thinner with the prolonged survival time. The correlation of the thickness detected by the above two methods was approximately (R 2 =0.8265). Value of the RNFL thickness in rats around optic disc measured by OCT was obviously higher than that measured by common histological measurement in normal adult rats and optic nerve transected rats. ·CONCLUSION: The RNFL thickness measured by OCT has a strong correlation with that measured by histological method. Through OCT scanning, we found that the thickness of RNFL gradually becomes thinner in a time-dependent manner.·AIM: To explore the correlation between the retinal nerve fiber layer (RNFL) thickness by using optical coherence tomography (OCT) and by histological measurements in normal adult rats and optic nerve transected rats. · METHODS: The RNFL thickness of 36 rats was scanned in a circle 3.46mm far from the optic disc by OCT. The two experimental groups were the normal group ( =20 rats) and the optic nerve transected group ( =16 rats). The latter group included 4 groups ( =4 /group) surviving for 1 day, 3, 5 and 7 days. Then the RNFL thickness of the same retina area was also measured by NF -200 immunohistochemical staining method. Linear regression was used to analyze the correlation between the data obtained from these two methods. ·RESULTS: The RNFL thickness of normal right eyes around optic disc by OCT was 72.35 ±5.71μm and that of the left eyes was 72.65 ±5.88μm ( =0.074). The RNFL thickness of the corresponding histological section by immunohistochemistry was 37.54 ±4.05μm (right eyes) and 37.38 ±4.23μm (left eyes) ( =0.059). There was a good correlation between the RNFL thickness measured by OCT and that measured by histology (R 2 =0.8131). After optic nerve transection, the trend of the RNFL thickness was thinner with the prolonged survival time. The correlation of the thickness detected by the above two methods was approximately (R 2 =0.8265). Value of the RNFL thickness in rats around optic disc measured by OCT was obviously higher than that measured by common histological measurement in normal adult rats and optic nerve transected rats. ·CONCLUSION: The RNFL thickness measured by OCT has a strong correlation with that measured by histological method. Through OCT scanning, we found that the thickness of RNFL gradually becomes thinner in a time-dependent manner.

关 键 词:retinal nerve fiber layer thickness optical coherence tomography optic nerve transection immunohistochemistry staining relevance analysis RAT 

分 类 号:R339.14[医药卫生—人体生理学]

 

参考文献:

正在载入数据...

 

二级参考文献:

正在载入数据...

 

耦合文献:

正在载入数据...

 

引证文献:

正在载入数据...

 

二级引证文献:

正在载入数据...

 

同被引文献:

正在载入数据...

 

相关期刊文献:

正在载入数据...

相关的主题
相关的作者对象
相关的机构对象