Comparative study of visual acuity and aberrations after intralase femtosecond LASIK:small corneal flap versus big corneal flap  被引量:4

Comparative study of visual acuity and aberrations after intralase femtosecond LASIK:small corneal flap versus big corneal flap

在线阅读下载全文

作  者:Ya-Li Zhang Lei Liu Chang-Xia Cui Ming Hu Zhao-Na Li Li-Jun Cao Xiu-Hua Jing Guo-Ying Mu 

机构地区:[1]Department of Ophthalmology,Shandong Provincial Hospital Affiliated to Shandong University [2]Department of Ophthalmology,the Second People's Hospital of Jinan [3]Department of Health Examination,Jinan Central Hospital Affiliated to Shandong University

出  处:《International Journal of Ophthalmology(English edition)》2013年第5期641-645,共5页国际眼科杂志(英文版)

摘  要:AIM:To study the effects of different flap sizes on visual acuity,refractive outcomes,and aberrations after femtosecond laser for laser in situ keratomileusis(LASIK).METHODS:In each of the forty patients enrolled,1 eye was randomly assigned to receive treatment with a 8.1mm diameter corneal flap,defined as the small flap,while the other eye was treated with a 8.6mm diameter corneal flap,defined as the big flap.Refractive errors,visual acuity,and higher-order aberrations were compared between the two groups at week 1,month 1 and 3 postoperatively. RESULTS:The postoperative refractive errors and visual acuity all conformed to the intended goal.Postoperative higher-order aberrations were increased,especially in spherical aberration(Z12) and vertical coma(Z7).There were no statistically significant differences between the two groups in terms of postoperative refractive errors,visual acuity,root mean square of total HOAs(HO-RMS),trefoil 30°(Z6),vertical coma(Z7),horizontal coma(Z8),trefoil 0°(Z9),and spherical aberration(Z12) at any point during the postoperative follow-up.CONCLUSION:Both the small and big flaps are safe and effective procedures to correct myopia,provided the exposure stroma meets the excimer laser ablations.The personalized size corneal flap is feasible,as we can design the size of corneal flap based on the principle that the corneal flap diameter should be equal to or greater than the sum of the maximum ablation diameter and apparatus error.AIM:To study the effects of different flap sizes on visual acuity,refractive outcomes,and aberrations after femtosecond laser for laser in situ keratomileusis(LASIK).METHODS:In each of the forty patients enrolled,1 eye was randomly assigned to receive treatment with a 8.1mm diameter corneal flap,defined as the small flap,while the other eye was treated with a 8.6mm diameter corneal flap,defined as the big flap.Refractive errors,visual acuity,and higher-order aberrations were compared between the two groups at week 1,month 1 and 3 postoperatively. RESULTS:The postoperative refractive errors and visual acuity all conformed to the intended goal.Postoperative higher-order aberrations were increased,especially in spherical aberration(Z12) and vertical coma(Z7).There were no statistically significant differences between the two groups in terms of postoperative refractive errors,visual acuity,root mean square of total HOAs(HO-RMS),trefoil 30°(Z6),vertical coma(Z7),horizontal coma(Z8),trefoil 0°(Z9),and spherical aberration(Z12) at any point during the postoperative follow-up.CONCLUSION:Both the small and big flaps are safe and effective procedures to correct myopia,provided the exposure stroma meets the excimer laser ablations.The personalized size corneal flap is feasible,as we can design the size of corneal flap based on the principle that the corneal flap diameter should be equal to or greater than the sum of the maximum ablation diameter and apparatus error.

关 键 词:femtosecond laser laser in situ keratomileusis refractive surgery FLAP visual acuity ABERRATION 

分 类 号:R779.63[医药卫生—眼科]

 