Clinical presentation of a mixed 23-gauge infusion and 20-gauge pars plana technique for active silicone oil removal  被引量:6

Clinical presentation of a mixed 23-gauge infusion and 20-gauge pars plana technique for active silicone oil removal

在线阅读下载全文

作  者:Jian-Qin Lei An-Ming Xie and Qiang Shi 

机构地区:[1]Department of Ophthalmology, the First Affiliated Hospital of the Medical College of Xi'an Jiaotong University, Xi'an 710061, Shaanxi Province, China

出  处:《International Journal of Ophthalmology(English edition)》2012年第5期600-604,共5页国际眼科杂志(英文版)

摘  要:AIM: To present with a clinical case series of a mixed 23-gauge infusion and 20-gauge pars plena technique for 5,700-centipoise silicone oil removal (SOR), and to discuss its efficacy and safety. METHODS: This is a retrospective, non-randomized controlled study. We performed SOR with 23-gauge infusion and 20-gauge active suction technique on 29 patients 29 eyes from April to October, 2011 (mixed group). During the surgeries, a 23-gauge sclerotomy was made for infusion and a 20-gauge sclerotomy was used for active silicone oil suction. Anterior segment optical coherence tomography (OCT) was applied for 23-gauge sclerotomy analysis 1 day post-operation. Traditional 20-gauge SOR was performed on another consecutive 29 patients 29 eyes, the control group (20G group). RESULTS: There were 2 eyes (6.9%) in mixed group and 5 eyes (17.2%) in 20G group which had recurrent retinal detachment after surgery. Hopytony (IOP <= 6mmHg) occurred in 8 eyes (27.6%) of mixed group and in 10 eyes (34.5%) of 20G group post-operation, but all of them recovered to the normal level finally. There were no statistical significant differences. Final visual acuity was significantly increased after surgery in both groups. Anterior segment OCT images were acquired from 13 eyes of mixed group, and all of them had a proper wound apposition. But local ciliary detachment was found in 9 eyes (69%). It was hard to define the OCT image of the sclerotomies and ciliary body because of the serious conjunctival hemorrhages and chemosis in 20G group. CONCLUSION: This mixed technique is a convenient and effective way to remove high viscosity silicone oil. Compared with traditional 20-gauge SOR, it does not increase the risk of post-operative complications and has less conjunctival reactions.. Transient postoperative hypotony is common for this procedure and subclinical ciliochoroidal detachment is a probable cause.AIM: To present with a clinical case series of a mixed 23-gauge infusion and 20-gauge pars plena technique for 5,700-centipoise silicone oil removal (SOR), and to discuss its efficacy and safety. METHODS: This is a retrospective, non-randomized controlled study. We performed SOR with 23-gauge infusion and 20-gauge active suction technique on 29 patients 29 eyes from April to October, 2011 (mixed group). During the surgeries, a 23-gauge sclerotomy was made for infusion and a 20-gauge sclerotomy was used for active silicone oil suction. Anterior segment optical coherence tomography (OCT) was applied for 23-gauge sclerotomy analysis 1 day post-operation. Traditional 20-gauge SOR was performed on another consecutive 29 patients 29 eyes, the control group (20G group). RESULTS: There were 2 eyes (6.9%) in mixed group and 5 eyes (17.2%) in 20G group which had recurrent retinal detachment after surgery. Hopytony (IOP <= 6mmHg) occurred in 8 eyes (27.6%) of mixed group and in 10 eyes (34.5%) of 20G group post-operation, but all of them recovered to the normal level finally. There were no statistical significant differences. Final visual acuity was significantly increased after surgery in both groups. Anterior segment OCT images were acquired from 13 eyes of mixed group, and all of them had a proper wound apposition. But local ciliary detachment was found in 9 eyes (69%). It was hard to define the OCT image of the sclerotomies and ciliary body because of the serious conjunctival hemorrhages and chemosis in 20G group. CONCLUSION: This mixed technique is a convenient and effective way to remove high viscosity silicone oil. Compared with traditional 20-gauge SOR, it does not increase the risk of post-operative complications and has less conjunctival reactions.. Transient postoperative hypotony is common for this procedure and subclinical ciliochoroidal detachment is a probable cause.

关 键 词:silicone oil removal 23-gauge HYPOTONY 

分 类 号:R779.6[医药卫生—眼科]

 

参考文献:

正在载入数据...

 

二级参考文献:

正在载入数据...

 

耦合文献:

正在载入数据...

 

引证文献:

正在载入数据...

 

二级引证文献:

正在载入数据...

 

同被引文献:

正在载入数据...

 

相关期刊文献:

正在载入数据...

相关的主题
相关的作者对象
相关的机构对象