励磁系统中积灰对晶闸管整流装置散热的影响分析  被引量:1

Analysis on the Impact of Ash Deposition on Heat Dissipation of Silicon Controlled Rectifying Device in Excitation Systems

在线阅读下载全文

作  者:刘伟[1] 许其品[1] 耿敏彪[1] 樊联[1] 

机构地区:[1]国电南瑞科技股份有限公司,江苏省南京市210003

出  处:《水电自动化与大坝监测》2013年第5期53-56,共4页HYDROPOWER AUTOMATION AND DAM MONITORING

摘  要:本文简单介绍了发电机励磁系统广泛采用的强迫风冷式晶闸管整流装置中晶闸管元件耗散功率的计算方法,并针对不同的风速以及散热器表面的清洁与否进行了对比性试验,根据试验数据细致地分析了风速以及散热器表面污垢对晶闸管散热器热阻的影响,对励磁系统的设计具有重要的指导意义。Forced air-cooled silicon controlled rectifying device is widely applied in generator excitation systems.The calculation method of dissipation power of silicon controlled component in the device is briefly introduced in this paper.Comparative experiments are conducted in the condition of different wind speed and in the condition that the surface of the radiator is clean or not.The influence on thermal resistance of thyristor radiator of wind speed and the dirt in the surface of radiator is analysed in detail,according to the experimental data.The research results provide significant reference for the design of excitation systems.

关 键 词:晶闸管散热器 强迫风冷 耗散功率 热阻 积灰 

分 类 号:TM6[电气工程—电力系统及自动化] TM3

 