YF-97防腐剂在催化裂化装置的应用  

The application of YF-97 anticorrosion agent on catalytic cracking unit

在线阅读下载全文

作  者:马永军[1] 

机构地区:[1]哈尔滨石化分公司,黑龙江哈尔滨150056

出  处:《炼油与化工》2004年第3期7-7,15,共2页Refining And Chemical Industry

摘  要:介绍了YF-97型防腐剂在哈尔滨石化分公司第三套催化裂化装置应用。通过对水样的分析结果表明:YF-97型防腐剂对催化分馏塔顶及吸收稳定系统的冷换设备和管线防腐效果较好;水样中的Fe2+浓度由1.51mg/L下降到0.26mg/L,pH值由9.40下降到9.00;降低了设备的维修费用,保证装置长周期运行,效益显著。The applications of YF-97 anticorrosion agent on the third catalytic cracking unit of Petrochina Harbin Petrochemical Branch Co.are introduced.The analyses on water samples indicate that YF-97 anticorrosion agent is very effective on the top of catalytic fractionating tower and heat exchange equipments and pipelines. The Fe2+ concentration in water samples is reduced from 1.51 mg/L to 0.26 mg/L, pH value is reduced from 9.40 to 9.00. With the lower equipments maintenance costs and longer unit running time, the benefit improvement is achieved.

关 键 词:防腐剂 催化裂化 腐蚀 

分 类 号:TE624.41[石油与天然气工程—油气加工工程]

 