机构地区:[1]华侨大学土木工程学院,福建泉州362021 [2]中国核工业部上海建筑设计院,上海200000
出 处:《华侨大学学报(自然科学版)》2005年第1期54-57,共4页Journal of Huaqiao University(Natural Science)
基 金:国家自然科学基金资助项目 (5 99790 1 8)
摘 要:根据钢筋锈蚀后砼的开裂状态 ,以及现有胀裂锈蚀量的计算模型特点 ,考虑砼相对保护层厚度的影响 ,提出一种更符合工程实际情况的砼胀裂时钢筋锈蚀量的计算模型 .经实例验证 ,该计算模型可行、有效 ,计算结果与实际情况相符合 .For computing corrosion rate of reinforcing bar following spalling of concrete cover, the authors present a model even more satisfying actual situation of engineering. The computation model is based on cracking state of concrete after corrosion of reinforcing bar; it directs against the characteristics of existing model for computing corrosion rate after spalling of concrete cover; and it takes the influence of relative thickness of concrete cover into consideration. The computation model is confirmed by living examples to be feasible and effective; its reckoning tallies with actual situation.
分 类 号:TU511.320[建筑科学—建筑技术科学]