某厂房楼面在动荷载作用下的振动测试  

Vibration measuring on the floors of a factory under machine excitation

在线阅读下载全文

作  者:沈朝勇[1] 任珉[1] 罗学海[1] 陈建秋[1] 谭平[1] 黄襄云[1] 

机构地区:[1]广州大学工程抗震研究中心,广东广州510405

出  处:《广州大学学报(自然科学版)》2004年第6期554-558,共5页Journal of Guangzhou University:Natural Science Edition

摘  要:根据现场实测结果,分析了受动荷栽作用的钢筋混凝土多层框架结构厂房楼面产生较大竖向振幅的 原因.结构加固后,为检测加固后的减振效果,对加固后结构再次进行了实地测试,通过对两次实测结果的对 比分析,结果表明:经加固后楼面竖向振动幅度大大降低,达到其减振目的.According to the measuring result in situ, the reason of vibration on a floor of a certain multilayer reinforced concrete frame factory is analyzed. After it is strengthened, vibration measuring also has been done. Results before strengthened and those after strengthened are analyzed, and the latter results are far less than the former, so the intention to decrease vertical vibration has been achieved.

关 键 词:厂房 竖向振动 测试 减振 

分 类 号:TU352.1[建筑科学—结构工程]

 