检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:陈海威[1] 殷济兰[1] 楼希荣[1] 顾菊康[1]
机构地区:[1]上海市第一人民医院心功能室,上海200080
出 处:《中国心血管杂志》1999年第3期131-132,共2页Chinese Journal of Cardiovascular Medicine
摘 要:目的 探讨电话传送心电图对室上性心动过速的诊断意义及方法的可靠性.方法 用Cardiobeeper电话心电图记录和接收装置(包括Survival导电橡胶电极)对9例室上速患者进行分析.结果 观察结果显示TTM、ECG、Holter对室上速的诊断分别为100.0%、0%、12.5%,TTM记录图形不失真.结论 TTM是一种对室上速可靠、有效、及时地辅助诊断技术.Objective To access the vaue and reliability of diagnosis of transer telephone eletrocardiography monitoring (TTM) for superventracular tachycardia (SVT). Methods 9 patients with superventracular tachycardia were examed by record and receive sets of Cardiobeeper, EKG and Holter. Results ratio of positive diagnosis of SVT with TTM、ECG、 Holter was 100. 0% , 0%、and 12. 5% respectively The graphs that had recorded by TTM were cleared and accurate. Conclusion TTM is a valuable method to diagnose SVT reliably and effectively.
关 键 词:心电图 室上速 室上性心动过速 诊断价值 TTM 辅助诊断 ECG 目的 方法 结论
分 类 号:R541[医药卫生—心血管疾病] R540.41[医药卫生—内科学]