作 者:梁国标[1] 李志清[1] 魏学忠[1] 唐新华[1] 邱海东 马建军[3]
机构地区:[1]中国人民解放军沈阳军区总医院神经外科,辽宁沈阳110016 [2]吉林市第三人民医院神经外科,吉林吉林132000 [3]本溪市本钢总医院神经外科,辽宁本溪117100
出 处:《中国微侵袭神经外科杂志》2005年第3期117-118,共2页Chinese Journal of Minimally Invasive Neurosurgery
摘 要:目的探讨Onyx胶在复杂脑动静脉畸形血管内治疗中的应用价值.方法采用Onyx胶栓塞11例复杂脑动静脉畸形,其中6例为巨大血管畸形,5例位于功能区.分析其血管构筑、栓塞技巧等.结果技术成功率100%,2例获90%栓塞,4例获80%以上栓塞,3例获50%~80%栓塞,2例栓塞小于50%.结论超选择插管Onyx胶栓塞术治疗脑动静脉畸形安全、有效.Objective To evaluate the application of endovascular therapy in the treatment of arterio-venous malformation (AVM) with Onyx glue. Methods Eleven complicated AVM patients, including 6 giant AVMs and 5 AVMs located in functional area, were enrolled in the study. Angioarchitecture and embolization technique were analyzed. Results The success rate reached 100%. Among the 11 patients, 2 acquired 90% embolization, four 80% embolization, three 50%-80% occlusion, and 2 less than 50% occlusion. Conclusion Endovascular treatment with Onyx glue can effectively improve the outcome of patients with AVM.