检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:朱伟[1] 侯建德 廖光煊[1] 卢平[1] 厉培德[1]
机构地区:[1]中国科学技术大学火灾科学国家重点实验室 [2]洛阳市消防支队
出 处:《中国安全科学学报》2004年第12期18-21,8,共5页China Safety Science Journal
摘 要:火灾烟气是导致多层建筑火灾中人员伤亡的主要原因。结合多层建筑的实际情况 ,利用缩尺度模型实验楼模拟多层建筑火灾的典型情况 ,对其火灾烟气自火源产生后的运动特性进行实验研究。结果表明 ,烟气沿程由于热交换温度不断降低 ,会迅速达到顶部楼层并立即沉降 ,而且不同工况条件下所包含的有毒成分浓度随着火源温度的升高而上升。实验结果的分析能够较好地符合实际火灾的一些典型调查结果。Fire smoke is an important causation resulted in many casualties in the fire of multi-floor buildings. Typical cases were simulated as multi-floor building fires by a reduced-scale experimental storied building model and the characteristics of fire smoke flow from fire source were studied by groups of experiments referring to actual environment. The results indicates that smoke temperature lowers continuously due to heat exchange, but smoke could rise to upper storey rapidly and sediment quickly, furthermore, the concentrations of toxic components of different cases involved could increase with the temperature of fire source increase. Analysis shows that the results comply well with the investigated findings of real fire.
关 键 词:多层建筑 火灾烟气 火源 楼层 沉降 情况 模型实验 运动 升高 实验研究
分 类 号:X524[环境科学与工程—环境工程] TU998[建筑科学—市政工程]