黄钠铁矾渣及其浸出液中铁的测定  被引量:4

The Assay of Iron in Iron Vitriol Dreg of Yellow Sodium and its Extract

在线阅读下载全文

作  者:唐吉旺[1] 黄坚[1] 

机构地区:[1]中南大学化学化工学院,长沙410083

出  处:《四川化工》2005年第3期40-42,63,共3页Sichuan Chemical Industry

摘  要:黄钠铁矾渣中铜的含量较高,用重铬酸钾容量法来测定渣样中的铁时,干扰铁的测定,需预分离才能准确测量。但在用铁还原法浸取渣样后的浸出液中,由于部分铜被除去,铜的含量降低,不干扰铁的测定,无需预分离,直接测定。实验结果表明,当铜占含铁量的4%时,干扰铁的测定。The quantum of copper in Iron Vitriol Dreg of yellow sodium is relatively high, so it interferes with the determination of iron in dreg by means of Potassium dichromate method. In order to get an accurate result ,we must separate it in advance. But in the extract coming from the process of soaking by iron reducing, because some copper has been removed and the its quantum became small, so it needs not to separate in advance and we can measure iron directly. The result of the experiment show that when the content of copper come to four percent it interferes with the determination of iron.

关 键 词:浸出液 铁矾渣 重铬酸钾容量法  准确测量 含量降低 直接测定 预分离 干扰 还原法 含铁量 

分 类 号:TF81[冶金工程—有色金属冶金]

 

参考文献:

正在载入数据...

 

二级参考文献:

正在载入数据...

 

耦合文献:

正在载入数据...

 

引证文献:

正在载入数据...

 

二级引证文献:

正在载入数据...

 

同被引文献:

正在载入数据...

 

相关期刊文献:

正在载入数据...

相关的主题
相关的作者对象
相关的机构对象