HL-2A装置可见光诊断方法初探  被引量:2

Initial analysis of the HL-2A tokamak visible light measurements

在线阅读下载全文

作  者:施乐[1] 郑银甲[1] 

机构地区:[1]核工业西南物理研究院,成都610041

出  处:《核聚变与等离子体物理》2005年第3期200-202,共3页Nuclear Fusion and Plasma Physics

摘  要:等离子体Hα径向分布的测量是等离子体实验中的重要内容。在HL-2A实验中,等离子体成像系统中的CCD图片记录了等离子体辐射信息,特别是Hα线辐射信息(在相机前加Hα滤光片)。因为光测量是辐射的线积分,数据的处理和分析显得十分必要的。利用等离子体可见光成像系统,采用Abel变换,得到Hα在HL-2A装置中的径向分布,提供了一项可靠的测量手段。Measurement of Hα radial distribution is an important part in a plasma experiment. During the HL-2A experiment, CCD photos recorded the plasma radiation information using a plasma imaging system, particularly the Hα line emission information (with Hα filter in front of the camera). Since the line of light radiation measurement involves a line integral of the radiating region, data handling and analysis are necessary. The Hα radial distribution along an HL-2A tokarnak radial radius can be obtained by using an Abel inversion transformation with plasma imaging on the HL-2A tokamak. This paper provides a reliable measurement method on the HL-2A tokamak.

关 键 词:ABEL变换 WIENER滤波 CCD成像 

分 类 号:O536[理学—等离子体物理]

 