衍射元件在大相对孔径红外镜头中的应用  被引量:2

Application of Diffractive Elements to Infrared Lenses of High Relative Aperture

在线阅读下载全文

作  者:欧旭锋[1] 舒朝濂[1] 

机构地区:[1]西安工业学院光电工程学院,西安710032

出  处:《西安工业学院学报》2006年第1期13-16,20,共5页Journal of Xi'an Institute of Technology

基  金:总装备部"十五"跨行业重点项目(41318.6.2.2.2)

摘  要:针对非制冷红外探测器的光学成像系统F/#-1左右的要求,分别采用三片式、两片式折射物镜为初始结构,结合像差理论,设计出了三款f=50mm,F/1,全视场角为10°,工作波段为8~12μm的红外物镜.前两款为折射物镜,后一款为折-衍混合物镜.设计结果表明:非球面和衍射面结合的折衍混合物镜可以替代传统的球面物镜,性能上也优于采用非球面的折射结构物镜.The requirement for the optical imaging system of the uncooled infrared detector is about F/ # = 1. To meet this requirement,two-element and three-element refractive lenses are adopted as the initial configurations,three kinds of lenses,which have parameters:f=50 mm,F/1,full FOV=10°,operat ing wavelength range is 8-12μm, are designed according to abervation theory The former two are refractive lenses, the latter one is a refractive-diffractive hybrid one. The design result indicates that the refractive-diffractive hyhrid lens with aspherical and diffractive elements can replace the traditional spherical lens,and is more excelled than the refractive lens with aspherical elements in performance.

关 键 词:非制冷红外探测器 衍射元件 红外折-衍混合物镜 

分 类 号:TN216[电子电信—物理电子学]

 