马钢3号高炉HT冷却壁破损分析  被引量:7

Investigation on breakage in HT cooling Staves of No.3 BF at Maanshan Iron & Steel Co.,Ltd.

在线阅读下载全文

作  者:胡源申[1] 袁晓敏[2] 王彪[2] 周炳圩 梁晓乾[3] 程静波[3] 薛晓天[3] 

机构地区:[1]华东冶金学院冶金系 [2]华东冶金学院 [3]马鞍山钢铁股份有限公司

出  处:《炼铁》1996年第2期1-5,共5页Ironmaking

摘  要:对马钢3号高炉第四代炉役HT冷却壁的破损进行了统计研究和扒炉调查。分析表明,对马钢300m^3级高炉,炉腹段冷却壁的总破损率是一个极其重要的、可作为评价高炉一代寿命进程的标志指标。当这一指标≥40%时,高炉进入晚期工作;≥80%时,高炉一代寿命终结。另根据扒炉调查结果,对冷却壁破损过程进行了初步分析。A statistieal study and a raking out investigation have been made on the breakage in HT cooling staves for the fourth campaign of No.3 BF at Maanshan Iron & Steel Co.,Ltd.The result shows that the total breakage rate of the cooling staves for bosh area can serve as a very important index to appraise one campaign life of the 300 rn3BF,The BF campaign comes into last stage when it is ≥10% and to an end when it is ≥80%.In addition the process of breakage in the cooling staves has been analysed preliminarily on the basis oi the results of raking out investigation.

关 键 词:高炉 冷却壁 破损 

分 类 号:TF321.4[冶金工程—冶金机械及自动化]

 

参考文献:

正在载入数据...

 

二级参考文献:

正在载入数据...

 

耦合文献:

正在载入数据...

 

引证文献:

正在载入数据...

 

二级引证文献:

正在载入数据...

 

同被引文献:

正在载入数据...

 

相关期刊文献:

正在载入数据...

相关的主题
相关的作者对象
相关的机构对象