检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:杨涛
出 处:《实用口腔医学杂志》2006年第5期599-603,共5页Journal of Practical Stomatology
摘 要:目的:探讨人工牙牙尖斜度对单侧游离端套筒冠义齿基牙位移的影响。方法:建立肯氏II类塑料模型,制作不同牙尖斜度的套筒冠义齿,在食片介在的咬合状态下垂直加载29.4、49、68.6N时,测量基牙位移值,通过计算求出各方向的位移、扭转量,最后进行统计分析。结果:解剖式人工牙与25°半解剖式人工牙相比,两基牙在颊舌向及垂直向位移差异有统计意义(P<0.05);解剖式人工牙与12°半解剖式人工牙相比,基牙在各方向的位移、倾斜、扭转差异均有统计意义(P<0.05);无尖人工牙与25°半解剖人工牙相比,除近远中向外,基牙的位移、倾斜、扭转差异均有统计意义(P<0.05);无尖人工牙与12°半解剖人工牙相比,基牙水平扭转程度差异无统计意义(P>0.05)。随负荷力增加,基牙位移量、倾斜角度、水平扭转角度也随之增加,各组之间差异有统计意义(P<0.05)。结论:套筒冠义齿修复下颌牙列单侧游离端缺损时,减小人工牙牙尖斜度,基牙在各轴向的位移、倾斜、扭转程度随之减小;基牙的位移量与负荷力大小有关。Objective:To study the influence of cusp inclination of artificial posterior teeth on abutment displacement of unilateral distal-extension telescope crown denture. Methods:Study models of mandibular unilateral distalextension and telescope crown dentures with the cusp inclination of 0°, 12°,25° and 33° were respectively prepared. When food chip was masticated on the occlusal surface and the dentures were loaded by 29.4 N, 49 N or 68.6 N, the abutment displacement was measured. Then the data were calculated and reciprocally compared with statistical analyses. Results:Between anatomic and 25° semi-anatomic artificial posterior teeth, there were significant differences in the buccolingual and vertical abutment movement( P 〈 0.05 ). There were significant differences in the abutment displacement on all three axes between anatomic and 12°semi-anatomic artificial posterior teeth (P 〈0.05). Between cuspless and 25°semi-anatomic posterior teeth, there were significant differences in abutment displacement on all three axes except the misiodistal direction (P 〈 0.05 ). Between cuspless and 12° semi-anatomic posterior teeth,there was no significant differences in the twist-like displacement( P 〉0.05 ). The parallel, inclination, twist-like and vertical movement of abutment increased with the increase of the load on the denture. The difference among different level of load was statistically significant ( P 〈 0.05 ). Conclusions: Abutment displacement can be reduced through reducing cusp inclination of artificial posterior teeth. The displacement of abutment correlates to the load on the denture.
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在链接到云南高校图书馆文献保障联盟下载...
云南高校图书馆联盟文献共享服务平台 版权所有©
您的IP:216.73.216.200