摘 要:低温热水地板辐射采暖系统具有节约能源、减少环境污染、热舒适性好、卫生保健、初投资不高、维修费用低等优点,但在应用中尚存在一些问题,本文指出了其在设计和施工中存在的一些问题及相应的解决方法,同时通过对共约2000m2实铺面积的统计,得出了不同管间距时单位面积大约所需的管长,根据经验提出了一种设计方法,该方法不仅可以使设计者节省设计时间,还可以避免管材浪费现象,节省工程成本。The low temperature hot water radiant floor heating system has many advantages such as energy-saving, reducing environmental pollution, comfortable, healthy, low investment and maintenance cost, but it still has some problems in application. Some problems and their solutions existing in design and construction have been pointed out in this paper. Meanwhile, through the statistics of the paving area about 2000 m^2, different pipe length needed by different pipe space of per area is picked up, and a design method is presented according to experience too. By this method, designers not only can save designing time, but also can avoid wasting materials and save the cost.