人胰岛素酶联免疫分析法的建立  被引量:1

The Establishment of an Enzyme Linked Immunosorbent Assay for Insulin

在线阅读下载全文

作  者:贾娟娟[1] 刘一兵[1] 陈键[1] 许文革[1] 官国英[1] 韩世泉[1] 

机构地区:[1]中国原子能科学研究院同位素研究所,北京102413

出  处:《同位素》2007年第1期24-28,共5页Journal of Isotopes

摘  要:采用两株抗胰岛素单克隆抗体,一株包被聚苯乙烯板、另一株标记辣根过氧化物酶,建立了测定人胰岛素的双抗体夹心酶联免疫分析法。方法学研究表明,本方法的灵敏度为1.7mIU/L,曲线范围5~160mIU/L,批内、批间变异系数分别小于11%、15%,回收率96.4%~111.1%;高浓度胰岛素血清样品系列倍比稀释后测定,测定值与稀释度呈线性相关,相关系数0.998;38例健康人血清样品测定值为3.6~10.8mIU/L。该方法与人胰岛素放射免疫分析法测定结果的相关性良好,r=0.97。Two monoclonal antibodies against insulin are applied in two-site enzyme linked immunosorbent assay (ELISA). One of the antibodies is immobilized on the microtiter plate, the other is labelled with HRP. The sensitivity of the assay is 1.7 mIU/L and the recovery is 96.4%~111.1%. The intra-and interassay CV are below 11% and 15.0% respectively. The correlation coefficient between measured and cliluted values is 0. 998 after serial dilutions of the samples using high concentration of insulin. The value for normal samples (n=38) is 3.6~10.8 mIU/L. Compared with RIA, the correlation coefficient is acceptable (r=0.97).

关 键 词:胰岛素 单克隆抗体 酶联免疫分析 放射免疫分析 

分 类 号:R392-33[医药卫生—免疫学] Q814.9[医药卫生—基础医学]

 